GB
Page 12 of 32
INSTRUCTION, USE AND
MAINTENANCE MANUAL
G1150.30MAGIC - G1150.30MAGICIT
RAVAGLIOLI S.p.A.
7107-M001-0_R
10.4 Working area modification
After the delivery, the machine is prearranged to operate
on wheel of 41” maximum diameter and a rim diameter
(10” - 26”). It’s also possible to move to move the base
as for the tools column to enlarge the working area from
43” (with rim diameter of 12” - 28”) to 45” (with rim
diameter of 14” - 30”) (see
Figure 11
).
Fig. 11
10.3 Electrical connection
As envisaged by the regulations in force, the machine is
not equipped with a master circuit breaker, but simply
has a plug-socket connection to the electrical mains.
The machine is supplied with
3
mt. of free cable. A plug
corresponding to the following requirements must be
connected to the cable:
• Conformity to Norm
IEC 309
•
230 Volt – 16A
•
2P + Ground
•
IP 44
On delivery, the machine is preset to operate at a voltage
of 200 ÷ 265 V - 50/60 Hz monophase.
EVEN THE TINIEST PROCEDURE OF
AN ELECTRICAL NATURE MUST BE
CARRIED OUT BY PROFESSION-
ALLY QUALIFIED STAFF.
BEFORE CONNECTING THE MA-
CHINE:
• MAKE SURE THAT THE POWER
MAINS RATING CORRESPONDS
TO THE MACHINE RATING AS
SHOWN ON THE MACHINE
PLATE;
• CHECK THAT ALL POWER MAINS
COMPONENTS ARE IN GOOD CON-
DITION;
• CHECK THAT THE ELECTRICAL
SYSTEM IS PROPERLY
GROUNDED (EARTH WIRE MUST
BE THE SAME CROSS-SECTION
AREA AS THE LARGEST POWER
SUPPLY CABLES OR GREATER);
• MAKE SURE THAT THE ELECTRI-
CAL SYSTEM FEATURES A CUT-
OUT WITH DIFFERENTIAL PRO-
TECTION SET AT 30 MA.
FIT A TYPE-APPROVED PLUG TO
THE MACHINE CABLE (THE EARTH
WIRE IS YELLOW/GREEN AND
MUST NEVER BE CONNECTED TO
THE PHASE LEADS). MAKE SURE
THAT THE ELECTRICAL SYSTEM IS
COMPATIBLE WITH THE RATED
POWER ABSORPTION SPECIFIED IN
THIS MANUAL AND APT TO EN-
SURE THAT VOLTAGE DROP UN-
DER FULL LOAD WILL NOT EXCEED
4% OF RATED VOLTAGE (10% UPON
START-UP).
FAILURE TO OBSERVE THE ABOVE
INSTRUCTIONS WILL IMMEDIATELY