Alarm messages and possible causes
5
78
10
Min.setting = 2.00
Max.setting = 50.00
Reference to the range of values for the
working width
.
Value entered is not permitted.
11
Min.setting = 0.40
Max.setting = 1.90
Reference to the value range of the
flow
factor
.
Value entered is not permitted.
12
Error during data transmis-
sion.
No RS232 connection.
An error has occurred during data transmis-
sion to the control unit.
The data have not been transmitted.
14
Error in Telimat device.
Alarm for the Telimat actuator.
The actuator cannot reach the target value
to be started.
Blockade
No position message
15
Memory is full.
Deletion of a private table
required
A maximum of 30 private tables can be
saved.
No additional saving possible
16
Move to drop point
Yes = START
Only for AXIS 50.1
W
: Safety request before automatic ap-
proach to the drop point.
Setting the drop point in
Fertiliser set-
tings
menu
Fast emptying
17
Error in drop point setting
The actuator for the drop point setting can-
not reach the set value to be moved to.
Blockade
No position message
21
Spreader overloaded
Only for weighing spreader:
the fertiliser
spreader is overloaded.
Too much fertiliser in the hopper
No. Message in display
Meaning
Possible cause
Summary of Contents for quantron e
Page 8: ...User instructions 1 6...