Operation Quantron E
43
4
4.4.5
Drop point (L+R)
When the Quantron E is connected to an
AXIS 50.1 W
fertiliser spreader, the
drop point is actuated and adjusted electrically.
1.
Switch from the
Fertiliser settings
menu to the
drop point L
menu.
2.
Determine the position for the drop point from the fertiliser chart.
3.
Input the determined value in the input field with the arrow keys:
Arrow up
: Value increases.
Arrow down
: Value decreases.
4.
Press the
Enter key
.
A message appears in the display asking for the new setting to be confir-
med.
See
5.1: Meaning of alarm messages, page 77
The fertiliser settings window appears in the display with the new drop point (L
and R).
If the drop point is blocked Alarm 17 appears; See
5.1: Meaning of alarm mes-
sages, page 77
.
NOTICE
Entering the drop point with the
AXIS 20.1, AXIS 30.1
or
AXIS 40.1
is merely
informative and does not affect the settings on the fertiliser spreader.
n
CAUTION
Danger of injury caused by automatic adjustment of
the drop point!
On the
AXIS 50.1 W
the alarm
move to drop point
intervenes.
After actuating the
Start/Stop
button, the drop point is automati-
cally approached using the electrical setting cylinder to the pre-set
value. This can cause injuries and material damage.
Before actuating the
Start/Stop
button, ensure that no one
is in the danger area of the machine.
NOTICE
Emergency actuation on the AXIS 50.1 must not stop the adjustment of the
drop point. Otherwise the setting unit for the drop point can suffer damage.