u
Adjust the position of the belt cleaner at the conveyor belt.
See
9.10 Adjusting the belt cleaner
u
Start the conveyor belt via the AXENT ISOBUS machine control unit.
u
Stop the conveyor belt after one minute.
u
Check the position of the conveyor belt at the tension roller and adjust, if necessary.
9.9.2
Setting the conveyor belt tension
n
Conveyor belt tension
u
Check the tension of the conveyor belt after the initial operating hours or if you detect a slipping
conveyor belt.
The tension rollers of the conveyor belt are located in front in the direction of travel between the
hopper and the frame.
u
Check the position of the disc spring
assemblies [2].
Nominal dimension in the pre-tensioned
installation position of all disc springs = 56
mm
Half of the disc spring assemblies are flush
to the positioning plate [1] on both sides.
28 mm +/- 1 mm,
10 disc springs
u
If necessary, retighten the disc springs.
Fig. 61: Retightening the disc spring assemblies
Checking the deflection roller position
The deflection roller has to be positioned in a right angle over the entire length.
9. Maintenance and service
AXENT 90.1
5903360
97
Summary of Contents for AXENT 90.1
Page 119: ...12 Appendix 12 Appendix AXENT 90 1 5903360 119...
Page 126: ......