Rebuilding the RAID with other non-RAID disk
If any of the SATA hard disk drives included in the RAID 1 array failed, the system displays the status
of the RAID volume as "Degraded" during POST. You can rebuild the RAID array with other installed
non-RAID disks.
To rebuild the RAID with other non-RAID disk:
1.
At the prompt, press <Ctrl> + <I> to enter the Intel Rapid Storage Technology option ROM
utility.
2.
If there is a non-RAID SATA Hard Disk available, the utility will prompt to rebuild the RAID.
Press <Enter>, and then use up/down arrow keys to select the destination disk or press
<ESC> to exit.
Figure 43-Rebuild RAID
Select a destination disk with the same size as the original hard disk.
3.
The utility immediately starts rebuilding after the disk is selected. The status
Figure 44- Select recovery disk
4.
of the degraded RAID volume is changed to "Rebuild".
5.
Exit Intel Rapid Storage Technology and reboot the system.
6.
Select Start > Programs > Intel Rapid Storage > Intel Rapid Storage Console or click the Intel