Chapter 4: KX III Administrator Help
101
a. Active - To activate the link once it is configured, select the
Active checkbox. Leave the checkbox deselected to keep the
link inactive. Entering information into the link fields and saving
can still be done even if Active is not selected. Once Active is
selected, the URL field is required. The username, password,
username field and password field are optional depending on
whether single sign-on is desired or not.
b. URL - Enter the URL to the interface. See Blade Chassis Sample
URL Formats for sample configurations for the Dell PowerEdge
1855/1955.
c. Username - Enter the username used to access the interface.
d. Password - Enter the password used to access the interface.
Note: Leave the username and password fields blank for DRAC, ILO,
and RSA web applications or the connection will fail.
e. The Username Field and Password Field, which are both
optional, contain the labels that are expected to be associated
with the username and password entries. It is in these fields you
should enter the field names for the username and password
fields used on the login screen for the web application. You can
view the HTML source of the login screen to find the field
names
,
not the field labels. See
Tips for Adding a Web Browser
Interface
(on page 105) for tips on adding a web browser
interface.
5. USB profiles do not apply to Dell chassis.
6. Click OK to save the configuration.
IBM Blade Chassis Configuration
See
Supported Blade Chassis Models
(on page 109),
Supported
CIMs for Blade Chassis
(on page 109), and
Required and
Recommended Blade Chassis Configurations
(on page 112) for
important, additional information when configuring the blade chassis.
See
Dell Chassis Cable Lengths and Video Resolutions
(on page
308) for information on cable lengths and video resolutions when using
Dell
®
chassis with the KX III.
To add a blade chassis:
1. Connect the blade chassis to the KX III. See Step 3: Connect the
Equipment for details.
2. Select Device Settings > Port Configuration to open the Port
Configuration page.
3. On the Port Configuration page, click on the name of the blade
chassis you want to configure. The Port page will open.
4. Select the Blade Chassis radio button. The page will then display the
necessary fields to configure a blade chassis.