EB200 Manual
Operation
4052.2000.02 3.47
E-7
3.18.5.1 IF-PAN (IF panorama)
This menu is obtained by pressing the IF PAN softkey in the DISPLAY menu, provided the optional
hardware EB200 SU (IF panorama) is installed.
IF-PAN (IF panorama) - CONFIG
This menu is obtained by pressing the CONFIG softkey in the IF-PAN menu.
Display parameter
LEVEL
Level measured on receive frequency
Configuration parameters
REF
The reference level sets the maximal level value that can be displayed. It can be
set within a range of -20 to 120 dBµV in steps of 10 dB.
RNG
The range value sets the range that can be displayed on the y-axis. It can be set
within a range of 10 to 160 dBµV in steps of 10 dB.
SPAN
The Span sets the width that can be displayed in the IF panorama in 17 steps
within the range of 150 Hz to 1000 kHz. In the COUPLED mode the displayed
width equals the width of the cut-in IF filter.
MTIME
Measuring time:
DEFAULT / 0.5 msec to 900 sec
Note:
A measuring time other than the DEFAULT can only be adjusted with IF sections that are fitted with the
DDC2 (see also "SYSTEM menu" on page 40).