EB200 Manual
Remote control
4052.2000.02 4.4
E-7
Device-specific commands
Hierarchy:
Device-specific commands are of hierarchical structure (see Fig. 4-1).
The different levels are represented by combined headers. Headers of
the highest level (root level) have only one keyword. This keyword
denotes a complete command system.
Example:
SENSe
This keyword denotes the command system
SENSe
.
For commands of lower levels, the complete path has to be specified,
starting on the left with the highest level, the individual keywords being
separated by a colon ":".
Example:
SENSe:FREQuency:STARt 118 MHz
This command lies in the third level of the SENSe system. It sets the
starting frequency of a scan to 118 MHz.
MODE
SENSe
DETector
BWIDth
FREQuency
STOP
FIXed
STEP
AFC
STARt
Fig. 4-1: Tree structure of the SCPI command system using the SENSe system
by way of an example