MIB Parameters
Appendix F
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
F-7
winlink1000OduSrvBridging
1.3.6.1.4.1.4458.1000.1.2.3
Integer
RO
Bridging Mode. Valid values are: disabled (0)
enabled (1).
winlink1000OduEthernetRemainingRate
1.3.6.1.4.1.4458.1000.1.3.1
Integer
RO
Current Ethernet bandwidth in bps.
winlink1000OduEthernetIfTable
N/A ODU Ethernet Interface table.
winlink1000OduEthernetIfEntry
N/A ODU Ethernet Interface table entry.
winlink1000OduEthernetIfIndex
1.3.6.1.4.1.4458.1000.1.3.2.1.1
Integer
RO
ODU Ethernet Interface Index.
winlink1000OduEthernetIfAddress
1.3.6.1.4.1.4458.1000.1.3.2.1.5
DisplayString
RO
ODU MAC address.
winlink1000OduEthernetIfAdminStatus
1.3.6.1.4.1.4458.1000.1.3.2.1.6
Integer
RW Required state of the interface.
winlink1000OduEthernetIfOperStatus
1.3.6.1.4.1.4458.1000.1.3.2.1.7
Integer
RO
Current operational state of the interface.
winlink1000OduEthernetIfFailAction
1.3.6.1.4.1.4458.1000.1.3.2.1.8
Integer
RW Failure action of the interface.
winlink1000OduEthernetNumOfPorts
1.3.6.1.4.1.4458.1000.1.3.3
Integer
RO
Number of ODU network interfaces.
winlink1000OduBridgeBasePortTable
N/A ODU Bridge Ports table.
winlink1000OduBridgeBasePortEntry
N/A ODU Bridge Ports table entry.
winlink1000OduBridgeBasePortIndex
RO
ODU Bridge Port Number.
winlink1000OduBridgeBaseIfIndex
RO
IfIndex corresponding to ODU Bridge port.
winlink1000OduBridgeTpMode
1.3.6.1.4.1.4458.1000.1.4.4.101
Integer
RW ODU bridge mode. A change is effective after
reset. Valid values: hubMode (0) bridgeMode (1).
winlink1000OduBridgeTpPortTable
N/A ODU Transparent Bridge Ports table.
winlink1000OduBridgeTpPortEntry
N/A ODU Transparent Bridge Ports table entry.
winlink1000OduBridgeTpPortIndex
RO
ODU Transparent Bridge Port Number.
winlink1000OduBridgeTpPortInFrames
1.3.6.1.4.1.4458.1000.1.4.4.3.1.3
Counter
RO
Number of frames received by this port.
winlink1000OduBridgeTpPortOutFrames
1.3.6.1.4.1.4458.1000.1.4.4.3.1.4
Counter
RO
Number of frames transmitted by this port.
winlink1000OduBridgeTpPortInBytes
1.3.6.1.4.1.4458.1000.1.4.4.3.1.10
1
Counter
RO
Number of bytes received by this port.
winlink1000OduBridgeTpPortOutBytes
1.3.6.1.4.1.4458.1000.1.4.4.3.1.10
2
Counter
RO
Number of bytes transmitted by this port.
winlink1000OduAirFreq
1.3.6.1.4.1.4458.1000.1.5.1
Integer
RW Installation Center Frequency. Valid values are
product dependent. A change is effective after link
re-synchronization.
winlink1000OduAirDesiredRate
1.3.6.1.4.1.4458.1000.1.5.2
Integer
RW Deprecated parameter actual behavior is read-
only. Required Air Rate. For Channel Bandwidth of
20 10 5 MHz divide the value by 1 2 4 respectively.
winlink1000OduAirSSID
1.3.6.1.4.1.4458.1000.1.5.3
DisplayString
RW Reserved for the Manager application provided
with the product.
winlink1000OduAirTxPower
1.3.6.1.4.1.4458.1000.1.5.4
Integer
RW Required Transmit power in dBm . This is a
nominal value while the actual transmit power
includes additional attenuation. The min and max
values are product specific. A change is effective
immediately.
winlink1000OduAirSesState
1.3.6.1.4.1.4458.1000.1.5.5
Integer
RO
Current Link State. The value is active (3) during
normal operation.
winlink1000OduAirMstrSlv
1.3.6.1.4.1.4458.1000.1.5.6
Integer
RO
This parameter indicates if the device was
automatically selected into the radio link master or
slave. The value is undefined if there is no link.
winlink1000OduAirResync
1.3.6.1.4.1.4458.1000.1.5.8
Integer
RW Setting this parameter to 1 will cause the link to
restart the synchronization process.
winlink1000OduAirRxPower
1.3.6.1.4.1.4458.1000.1.5.9.1
Integer
RO
Received Signal Strength in dBm.
winlink1000OduAirTotalFrames
1.3.6.1.4.1.4458.1000.1.5.9.2
Counter
RO
Total Number of received radio frames.
winlink1000OduAirBadFrames
1.3.6.1.4.1.4458.1000.1.5.9.3
Counter
RO
Total number of received radio frames with CRC
error.
winlink1000OduAirCurrentRate
1.3.6.1.4.1.4458.1000.1.5.9.4
Integer
RO
Deprecated parameter. Actual rate of the air
interface in Mbps. For Channel Bandwidth of 20 10
5 MHz divide the value by 1 2 4 respectively.
Table F-2: Private MIB Parameters (Sheet 3 of 14)
Name
OID
Type
Access
Description