MIB Parameters
Appendix F
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
F-17
winlink1000IduTdmLineCoding
1.3.6.1.4.1.4458.1000.2.6.6.1.6
Integer
RW This parameter applies to T1 trunks only. The
parameter controls the line coding. Setting the
value to each of the indices applies to all. A
change is effective after the next open of the TDM
service.
winlink1000IduTdmLoopbackConfig
1.3.6.1.4.1.4458.1000.2.6.6.1.9
Integer
RW Loop back configuration table. Each of the trunks
can be set Normal Line loop back or Reverse line
loop back. A change is effective immediately.
winlink1000IduTdmLineStatus
1.3.6.1.4.1.4458.1000.2.6.6.1.10
Integer
RO
Line status.
winlink1000IduTdmCurrentTable
N/A IDU TDM Links Statistics table.
winlink1000IduTdmCurrentEntry
N/A IDU TDM Links Statistics table entry.
winlink1000IduTdmCurrentIndex
RO
Table index (Same as
winlink1000IduTdmLineIndex).
winlink1000IduTdmCurrentBlocks
1.3.6.1.4.1.4458.1000.2.6.7.1.101
Counter
RO
Number of correct blocks transmitted to the line.
winlink1000IduTdmCurrentDrops
1.3.6.1.4.1.4458.1000.2.6.7.1.102
Counter
RO
Number of error blocks transmitted to the line.
winlink1000IduTdmCurrentTxClock
1.3.6.1.4.1.4458.1000.2.6.7.1.103
Integer
RW TDM Transmit Clock. A change is effective after
re-activation of the TDM service.
winlink1000IduTdmCurrentBlocksHigh
1.3.6.1.4.1.4458.1000.2.6.7.1.104
Counter
RO
High part of the 64 bits counter Current Blocks
winlink1000IduTdmRemoteQual
1.3.6.1.4.1.4458.1000.2.6.8
Integer
RO
Estimated average interval between error second
events. The valid values are 1-2^31 where a value
of -1 is used to indicate an undefined state.
winlink1000IduTdmRemoteQualEval
1.3.6.1.4.1.4458.1000.2.6.9
Integer
RO
Estimated average interval between error second
events during evaluation process. The valid values
are 1-2^31 where a value of -1 is used to indicate
an undefined state.
winlink1000IduTdmSrvEval
1.3.6.1.4.1.4458.1000.2.6.10
Integer
RW Evaluated TDM service bit mask. Setting this
parameter to value that is bigger than the activated
TDM service bit mask will execute the evaluation
process for 30 seconds. Setting this parameter to
0 will stop the evaluation process immediately.
winlink1000IduTdmBackupAvailableLinks 1.3.6.1.4.1.4458.1000.2.6.11
Integer
RO
Number of TDM backup trunks.
winlink1000IduTdmBackupTable
N/A IDU TDM Links Statistics table.
winlink1000IduTdmBackupEntry
N/A IDU TDM Links Statistics table entry.
winlink1000IduTdmBackupIndex
1.3.6.1.4.1.4458.1000.2.6.12.1.1
Integer
RO
Table index.
winlink1000IduTdmBackupMode
1.3.6.1.4.1.4458.1000.2.6.12.1.2
Integer
RW TDM backup mode: Enable or Disable where the
main link is the air link or the external link.
Changes will be effective immediatly.
winlink1000IduTdmBackupCurrentActive
Link
1.3.6.1.4.1.4458.1000.2.6.12.1.3
Integer
RO
TDM backup current active link: N/A air link is
active or external link is active.
winlink1000IduTdmJitterBufferSize
1.3.6.1.4.1.4458.1000.2.6.13
Integer
RW TDM Jitter Buffer Size. The value must be
between the minimum and the maximum TDM
Jitter Buffer Size. The units are 0.1 x millisecond.
winlink1000IduTdmJitterBufferDefaultSiz
e
1.3.6.1.4.1.4458.1000.2.6.14
Integer
RO
TDM Jitter Buffer Default Size. The units are 0.1 x
millisecond.
winlink1000IduTdmJitterBufferMinSize
1.3.6.1.4.1.4458.1000.2.6.15
Integer
RO
TDM Jitter Buffer Minimum Size. The units are 0.1
x millisecond.
winlink1000IduTdmJitterBufferMaxSize
1.3.6.1.4.1.4458.1000.2.6.16
Integer
RO
TDM Jitter Buffer Maximum Size. The units are 0.1
x millisecond.
winlink1000IduTdmJitterBufferSizeEval
1.3.6.1.4.1.4458.1000.2.6.17
Integer
RW TDM Jitter Buffer Size for evaluation. The value
must be between the minimum and the maximum
TDM Jitter Buffer Size. The units are 0.1 x
millisecond.
winlink1000IduTdmType
1.3.6.1.4.1.4458.1000.2.6.18
Integer
RW TDM Type (The value undefined is read-only).
winlink1000IduTdmTypeEval
1.3.6.1.4.1.4458.1000.2.6.19
Integer
RW TDM Type for evaluation.
winlink1000IduTdmLineStatusStr
RO
Line status.
Table F-2: Private MIB Parameters (Sheet 13 of 14)
Name
OID
Type
Access
Description