MIB Parameters
Appendix F
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
F-16
winlink1000IduSrvAvailServicesReason
1.3.6.1.4.1.4458.1000.2.2.11.1.5
Integer
RO
Information about the TDM Service availability. -
Not Applicable if the service is available. The
reasons for TDM Service unavailability: - The
available throughput isn't sufficient for Service
demands; - The IDU HW doesn't support the
service; - A Link Password mismatch was
detected; - The external pulse type detected is
improper for TDM services; - A Software versions
mismatch was detected.
winlink1000IduSrvEthActive
1.3.6.1.4.1.4458.1000.2.2.12
Integer
RO
Represents the Ethernet service activation state.
winlink1000IduSrvEthAvailable
1.3.6.1.4.1.4458.1000.2.2.13
Integer
RO
Represents the Ethernet service availability state.
winlink1000IduSrvEthThroughput
1.3.6.1.4.1.4458.1000.2.2.14
Gauge
RO
Current available Ethernet service throughput in
bps.
winlink1000IduSrvEthMaxInfoRate
1.3.6.1.4.1.4458.1000.2.2.15
Integer
RW Holds the maximum bandwidth (kbps) to be
allocated for Ethernet service. Value of zero
means that Ethernet service works as best effort.
The maximum value is product specific. Refer to
the user manual.
winlink1000IduEthernetIfTable
N/A IDU Ethernet Interface table.
winlink1000IduEthernetIfEntry
N/A IDU Ethernet Interface table entry.
winlink1000IduEthernetIfIndex
RO
If Index corresponding to this Interface.
winlink1000IduEthernetIfAddress
1.3.6.1.4.1.4458.1000.2.3.1.1.5
DisplayString
RO
IDU MAC address.
winlink1000IduEthernetNumOfLanPorts
1.3.6.1.4.1.4458.1000.2.3.3
Integer
RO
Number of LAN interfaces in the IDU.
winlink1000IduBridgeTpAging
1.3.6.1.4.1.4458.1000.2.4.4.2
Integer
RW Timeout in seconds for aging. Note that for this
parameter to be effective the ODU must be
configured to HUB mode. A change is effective
immediately.
winlink1000IduTdmTxClockAvailStates
1.3.6.1.4.1.4458.1000.2.6.1.1
Integer
RO
Available states of the TDM Transmit Clock
Control each input status is represented by a bit.
When the state is available the bit value is 1. When
the state is unavailable the bit value is 0. The
available states are: bit 2 = Transparent. bit 3 =
Local Loop Timed. bit 4 = Remote Loop Timed. bit
5 = Local Internal. bit 6 = Remote Internal.
winlink1000IduTdmTxClockDesiredState
1.3.6.1.4.1.4458.1000.2.6.1.2
Integer
RW Required state of the TDM Transmit Clock Control.
A change is effective after re-activation of the TDM
service.
winlink1000IduTdmTxClockActualState
1.3.6.1.4.1.4458.1000.2.6.1.3
Integer
RO
Actual state of the TDM Transmit Clock Control.
winlink1000IduTdmMasterClockAvailOpti
ons
1.3.6.1.4.1.4458.1000.2.6.2.1
Integer
RO
Available options of the TDM Master Clock Control
each input status is represented by a bit. When the
option is available the bit value is 1. When the
option is unavailable the bit value is 0. The
available options are: bit 2 = Automatic. bit 3 =
Trunk #1. bit 4 = Trunk #2. bit 5 = Trunk #3. bit 6 =
Trunk #4. When no options are available the
returned value is: 1
winlink1000IduTdmMasterClockDesired
1.3.6.1.4.1.4458.1000.2.6.2.2
Integer
RW Required TDM Master Clock. A change is effective
after re-activation of the TDM service.
winlink1000IduTdmMasterClockActual
1.3.6.1.4.1.4458.1000.2.6.2.3
Integer
RO
Actual Trunk used for TDM Master Clock.
winlink1000IduTdmConfigTable
N/A IDU TDM Links Configuration table.
winlink1000IduTdmConfigEntry
N/A IDU TDM Links Configuration table entry.
winlink1000IduTdmConfigIndex
RO
Table index.
winlink1000IduTdmIfIndex
RO
Link index in the interface table.
Table F-2: Private MIB Parameters (Sheet 12 of 14)
Name
OID
Type
Access
Description