MIB Parameters
Appendix F
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
F-13
winlink1000OduPerfMonTdmCurrActiveS
econds
RO
Parameter indicating whether the TDM service
was active. Under TDM backup link the parameter
indicates whether the backup link was active.
winlink1000OduPerfMonTdmIntervalTabl
e
N/A This table defines/keeps the counters of the
current 15 min interval.
winlink1000OduPerfMonTdmIntervalEntr
y
N/A This is an entry in the Interval Table.
winlink1000OduPerfMonTdmIntervalIdx
RO
This table is indexed per interval number. Each
interval is of 15 minutes and the oldest is 96.
winlink1000OduPerfMonTdmIntervalActiv
eSeconds
RO
Parameter indicating whether the TDM service
was active. Under TDM backup link the parameter
indicates whether the backup link was active.
winlink1000OduPerfMonTdmDayTable
N/A This table defines/keeps the counters of the
current 15 min interval.
winlink1000OduPerfMonTdmDayEntry
N/A This is an entry in the Days Table.
winlink1000OduPerfMonTdmDayIdx
RO
This table is indexed per Day number. Each Day is
of 15 minutes and the oldest is 96.
winlink1000OduPerfMonTdmDayActiveS
econds
RO
Parameter indicating whether the TDM service
was active. Under TDM backup link the parameter
indicates whether the backup link was active.
winlink1000OduPerfMonTxThresh1
1.3.6.1.4.1.4458.1000.1.6.20
Integer
RW When the Transmit power exceeds this threshold a
performance monitoring TSL1 counter is
incremented.
winlink1000OduPerfMonRxThresh1
1.3.6.1.4.1.4458.1000.1.6.21
Integer
RW When the RX power exceeds this threshold a
performance monitoring RSL1 counter is
incremented.
winlink1000OduPerfMonRxThresh2
1.3.6.1.4.1.4458.1000.1.6.22
Integer
RW When the RX power exceeds this threshold a
performance monitoring RSL2 counter is
incremented.
winlink1000OduPerfMonBBERThresh1
1.3.6.1.4.1.4458.1000.1.6.23
Integer
RW When the BBER exceeds this threshold a
performance monitoring BBER counter is
incremented. The units are 1/10 of a percent.
winlink1000OduAgnGenAddTrapExt
1.3.6.1.4.1.4458.1000.1.7.1.1
Integer
RW If 'yes' is chosen the ifIndex Unit Severity Time_T
and Alarm Id from the
winlink1000OduAgnCurrAlarmTable will be bind to
the end of each private trap.
winlink1000OduAgnNTPCfgTimeServerI
P
1.3.6.1.4.1.4458.1000.1.7.2.1
IpAddress
RW IP address of the server from which the current
time is loaded.
winlink1000OduAgnNTPCfgTimeOffsetFr
omUTC
1.3.6.1.4.1.4458.1000.1.7.2.2
Integer
RW Offset from Coordinated Universal Time (minutes).
Possible values: -1440..1440.
Table F-2: Private MIB Parameters (Sheet 9 of 14)
Name
OID
Type
Access
Description