MIB Parameters
Appendix F
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
F-11
winlink1000OduPerfMonDayTable
N/A This table defines/keeps the counters of the
current 15 min interval.
winlink1000OduPerfMonDayEntry
N/A This is an entry in the Days Table.
winlink1000OduPerfMonDayIdx
RO
This table is indexed per interval number. Each
interval is of 24 hours and the oldest is 30.
winlink1000OduPerfMonDayUAS
RO
The current number of Unavailable Seconds per
interval of 24 hours.
winlink1000OduPerfMonDayES
RO
Current number of Errored Seconds per interval of
24 hours.
winlink1000OduPerfMonDaySES
RO
Current number of Severely Errored Seconds per
interval of 24 hours.
winlink1000OduPerfMonDayBBE
RO
Current number of Background Block Errors per
interval of 24 hours.
winlink1000OduPerfMonDayIntegrity
RO
Indicates the integrity of the entry per interval of 24
hours.
winlink1000OduPerfMonAirCurrTable
N/A This table defines/keeps the counters of the
current 15 min interval.
winlink1000OduPerfMonAirCurrEntry
N/A This is an entry in the Current Interval Table.
winlink1000OduPerfMonAirCurrMinRSL
1.3.6.1.4.1.4458.1000.1.6.4.1.1
Integer
RO
Current Min Received Level Reference starting
from the present 15 minutes period.
winlink1000OduPerfMonAirCurrMaxRSL
1.3.6.1.4.1.4458.1000.1.6.4.1.2
Integer
RO
Current Max Received Level Reference starting
from the present 15 minutes period.
winlink1000OduPerfMonAirCurrRSLThre
sh1Exceed
1.3.6.1.4.1.4458.1000.1.6.4.1.3
Gauge
RO
Number of seconds Receive Signal Level
exceeded the RSL1 threshold in the last 15
minutes.
winlink1000OduPerfMonAirCurrRSLThre
sh2Exceed
1.3.6.1.4.1.4458.1000.1.6.4.1.4
Gauge
RO
Number of seconds Receive Signal Level
exceeded the RSL2 threshold in the last 15
minutes.
winlink1000OduPerfMonAirCurrMinTSL
1.3.6.1.4.1.4458.1000.1.6.4.1.5
Integer
RO
Current Min Transmit Signal Level starting from
the present 15 minutes period.
winlink1000OduPerfMonAirCurrMaxTSL
1.3.6.1.4.1.4458.1000.1.6.4.1.6
Integer
RO
Current Max Transmit Signal Level starting from
the present 15 minutes period.
winlink1000OduPerfMonAirCurrTSLThre
sh1Exceed
1.3.6.1.4.1.4458.1000.1.6.4.1.7
Gauge
RO
Number of seconds Transmit Signal Level
exceeded the TSL1 threshold in the last 15
minutes.
winlink1000OduPerfMonAirCurrBBERThr
esh1Exceed
1.3.6.1.4.1.4458.1000.1.6.4.1.8
Gauge
RO
Number of seconds Background Block Error Ratio
exceeded the BBER1 threshold in the last 15
minutes.
winlink1000OduPerfMonAirIntervalTable
N/A This table defines/keeps the counters of the
current 15 min interval.
winlink1000OduPerfMonAirIntervalEntry
N/A This is an entry in the Interval Table.
winlink1000OduPerfMonAirIntervalIdx
RO
This table is indexed per interval number. Each
interval is of 15 minutes and the oldest is 96.
winlink1000OduPerfMonAirIntervalMinRS
L
RO
Current Min Received Level Reference per
interval.
winlink1000OduPerfMonAirIntervalMaxR
SL
RO
Current Max Received Level Reference per
interval.
winlink1000OduPerfMonAirIntervalRSLT
hresh1Exceed
RO
Number of seconds Receive Signal Level
exceeded the RSL1 threshold per interval.
winlink1000OduPerfMonAirIntervalRSLT
hresh2Exceed
Number of seconds Receive Signal Level
exceeded the RSL2 threshold ACCESS read-only
per interval.
winlink1000OduPerfMonAirIntervalMinTS
L
RO
Current Min Transmit Signal Level per interval.
Table F-2: Private MIB Parameters (Sheet 7 of 14)
Name
OID
Type
Access
Description