WinLink 1000 Installation and Operation Manual
Chapter 5 Diagnostics and Troubleshooting
Q: In BAND C, can you add the frequency of 5.735 to the manual
selection in order to increase the number of 20 MHz channels to six?
A: Currently the system provides 5 fixed channels. Yet, the manual
frequency setting provides more flexibility of spectrum selection,
including 5.735 MHz.
Q: Can I use the WinLink 1000 with any vendor external antenna?
A: Yes. RADWin supplies the WinLink 1000 external ODU with an N-
type typical connector. Any vendor external antenna that can be
cascaded to our external unit can be use without problem. Please note
that dB losses in the cascading cable between the external ODU and
antenna should be taken into consideration. (In the supplied cascading
cable of one meter we have 1 dB loss)
Q: Do we need to add external arrestors on WinLink 1000 cables?
A: The WinLink ODU includes arrestors and lightning protection.
Therefore there is no need to add additional arrestors.
Q: What is the sensitivity for each rate of the WinLink 1000?
A: The sensitivities are:
Rate 12 Mbps -84 dB
Rate 18 Mbps -81 dB
Rate 36 Mbps -74 dB
Rate 48 Mbps -68 dB
Q: Does WinLink 1000 use DSSS technique?
A: No, WinLink 1000 uses the advanced OFDM technique.
Management
Q: Can we mange WinLink 1000 using SNMP other then the supplied
management software that comes with the units?
A: Yes. The WinLink 1000 is SNMP based, when using other SNMP
software, and after implementing RADWin MIB’s, the WinLink 1000 can
be managed.
Q: Can WinLink 1000 be managed and configured via Telnet?
A: No. Use only the WinLink software manager.
PM
Frequently Asked Questions
5-9