WinLink 1000 Installation and Operation Manual
Quick Start Guide
Operating WinLink 1000
5
Troubleshooting
If the WinLink 1000 is not operational, determine the cause and solution
from the table below.
Led Status
Remedy
PWR
Off
For the IDU-E, check that AC adapter is connected
to the IDU and the AC power outlet.
IDU
Orange
Check that the IDU/ODU cable is properly wired
and connected.
ODU
Red
Check that the IDU/ODU cable is properly wired
and connected.
Orange
Complete the installation procedure from the
management software.
AIR I/F
Red
Check the ODU Antenna alignment. Check that
the radio configuration of both site A and site B
units are the same (channel and SSID).
Off
Check the TDM service configuration in the NMS.
Orange
Check that the system is not in loopback mode.
Check the site B IDU ports and cables and site B
external equipment.
SVC.
Red
Check the site A IDU ports, cables and external
equipment.