16
1. Rada Pulse Control Box
material: plastic sealed to ip54.
Voltage: 230 V ac, 50/60 hz.
Transformer: 230 V ac/12 V ac.
rating: 120 Va.
main fuse: T 2.5 a h 250 V
(
Important!
use only rada approved fuse, part no. 422.84)
10 x inputs suitable for pulse sensors.
10 x solenoid outputs, 12 V ac selV (5 fuses) - fused at 2.5 a for each pair.
door switch input (normally closed)
disable switch input (normally open)
disinfection enable input
3 x auxiliary outputs, 12V ac selV (1 fuse) - fused at 400 ma, for connection to
rada pulse relay box:
fan output
•
light output
•
pump output
•
1 x disinfection Valve output
ambient Temperature range: 0 - 40°c.
maximum humidity: 80% at 25°c.
Type of action: Type 1.
suitable for continuous use.
software/firmware: class a control function.
2. Rada Pulse sensors
2.1 Rada Pulse 120/122 sensors
material: plastic shell, finish: chrome plated.
3 m of 2 core sheathed cable with connections sealed into the sensor.
operating voltage: 12 V ac. via the 2 core cable.
fixing holes for 2 x 6 mm dome headed screws (supplied).
protection: ip67.
Temperature range: 4 to 70°c.
activation distance
-120 sensor 0 to 50 mm.
-122 sensor 0 to 550 mm.
The distance is dependent on the reflectivity of the detected object.
sPeCIFICATIONs