8. Diagnostics
8.1. Overview
The Overview section serves to give general information about the RipEX2.
8.1.1. Measurements
Section Overview - Measurements contains current data measurement (obtained from sensors).
• Card Temperature - provides data about temperature (on CPU, modem and radio).
Note
If the temperature exceeds its specified range (-45 – +95°C), the radio receiving/transmitting
will be blocked. If the temperature will return to a specified range (-40 – +85°C), the radio
starts receiving/transmitting again.
This feature can be disabled in parameters Advanced > Interfaces > Radio > Radio paramet-
ers > Block radio in extreme temperatures.
• Card Voltage - provides data about voltage measured on input connector.
Arrow-headed symbols (↑, ↓, →) have following meaning:
• ↑ - Maximum-limit value. An alarm is triggered, when the value (displayed in brackets) is exceeded.
• ↓ - Minimum-limit value. An alarm is triggered, when the value falls under the value, which is displayed
in the brackets.
• →- Value is supposed to head to another one.
Note
Value measurements are collected once per 10s (excluding radio interface, where values can
be collected once per 10s or more often – depends on the radio communication character).