7
AA RTU Interior View Call-outs
Call-out
Specification
Test Call Pushbutton
Press this pushbutton when you want to test
the connection between the RTU and
AlarmAgent.com. Pressing this button will
send a message to the website, requesting a
test call be generated to the “Notification
Phone Number for Test Calls” configured
on the “System Wide Settings” page and is
REQUIRED or test calls will be DISABLED.
Test Call LED
[Green]
OFF = Test Call Pushbutton disabled
ON = Test Call Pushbutton enabled
Signal Strength Indicator
[Red]
Each LED represents 10% of maximum
signal. For example, 7 LEDs illuminated
translates to 70% signal strength.
Armed / Disarmed
Pushbutton
Push this button when you want to Disarm or
Arm the RTU. The ARM LED is green when
the unit is armed. The ARM LED is red when
the unit is disarmed.
Status LED – Alarm
[Red]
OFF = No Alarm Criteria violated
ON = Alarm Criteria violated
Status LED – Violation
[Amber]
OFF = No Alarm Criteria violated
ON = Alarm Criteria has been violated, but
waiting for Alarm Trip Delay to time-out
Status LED – Suspended
[Red Blinking]
OFF = No Channels Suspended
ON = Number of channel transitions allowed
per day exceeded
Battery Disconnect Jumper
JP6
Right-Side Jumper placement = Battery
disconnected for shipping or long-term
storage.
Left-Side Jumper placement = Battery
connected, ready for use
Remote ON / OFF Option
P7
This option allows the RTU be remotely
turned ON or OFF. For more information,
please contact your RACO representative.
Power Present LED
[Amber]
ON = Power present
OFF = No power present
Accept Pushbutton
Press this pushbutton when all wired inputs
are in a NORMAL condition. Channel criteria
set to current condition.
Summary of Contents for AlarmAgent.com AA-102DC
Page 1: ...RACO MANUFACTURING ENGINEERING COMPANY AA RTU Installation Manual v3 2...
Page 6: ...5...
Page 7: ...6 RTU Interior View...
Page 34: ...33 Solar Power Mode Wiring Diagram...
Page 35: ...34...
Page 36: ...35...
Page 37: ...36...
Page 40: ......
Page 41: ...40 Appendix G AlarmAgentTM RTU Digital Upgrade Field Wiring Worksheets...
Page 42: ...41...