IQ3 Data Logger Dash Installation Manual
42
Programming the Warnings
The IQ3 Drag Dash provides the ability to program up to four individual warning channels. The
face of the dash contains four warning lights. Each warning light is associated with a single
warning channel. To program each individual warning channel:
1.
Select the “Warnings” tab.
2.
Next, left click on the warning light you would like to program. This action will open
the Warning Light text box.
Warning Parameter
Description
Warning Channel
Sensor input to be used to trigger warning.
Low Warning Limit
Sensor value to trigger warning when below this value.
High Warning Limit
Sensor value to trigger warning when above this value.
Channel Tag
Text to be displayed above warning channel value when
warning is activated. 5 chars max.
Channel Value is Inside
Warning Limit Window
Triggers warning when sensor value is between Low and High
Warning limits.
Channel Value is Outside
Warning Limit Window
Triggers warning when sensor value is below Low Warning
Limit and above High Warning Limit.
Warning Input 1 AND
Warning Input 2 Conditions
Are Met
Requires that warning 1
AND
warning 2 conditions are met to
activate warning.
Warning Input 1 OR
Warning Input 2 Conditions
Are Met
Requires that warning 1
OR
warning 2 conditions are met to
activate warning.
Warning Tag
Text displayed to the left of warning channel value(s) when
warning is activated. 5 chars max.
On Delay Time
Time is seconds to delay before warning is activated.
Turn On External Warning
Turns on external warning when warning channel is activated.