IQ3 Drag Dash Installation Manual
27
Setting as
Displayed on
Dash
Program
Setting Description
Programming
Command
Accept and
Advance
Accept and
Exit
WARN -
COOLANT TEMP
High Water temp warning value
Value to be used for control of
High H2O temp Light (Lower Left
LED)
Factory Default is 200
Short Press Button 2
Increases by 1
Medium Press Button 2
Decreases by 10
Short Press
Button 1
Long Press
Button 1
WARN -
OIL PRESS
Low oil pressure warning value
Value to be used for control of
Low oil pressure Light
Factory Default is 20
Short Press Button 2
Increases by 1
Medium Press Button 2
Decreases by 10
Short Press
Button 1
Long Press
Button 1
FAN ON TEMP
Fan On Output value
Value to be used for control for
fan output
Factory Default is 180
Short Press Button 2
Increases by 1
Medium Press Button 2
Decreases by 10
Short Press
Button 1
Long Press
Button 1
FAN OFF TEMP
Fan Off Output value
Value to be used for control for
fan output
Factory Default is 175
Short Press Button 2
Increases by 1
Medium Press Button 2
Decreases by 10
Short Press
Button 1
Long Press
Button 1
Display Clock/Time:
Clock/Time is available for viewing anytime the IQ3 Drag Dash is powered on and not in any
setup modes. By default, it is displayed in the upper right area only when the button 1 is held
down for a set period of time, roughly 3 seconds. Regardless of what parameter is programmed
in that upper right area, the location of the clock cannot be changed.
To view clock
1.
At any point, in normal viewing mode, Press and hold either button for THREE light
blinks – LONG press
2.
As long as the button is held, the display will show the time which was set in the Setup 1
programming menu.
To set the time, see Entering Setup Mode section found on
page 23
.