SCPI Command Reference 4-22
-148,"Character data not allowed". A character data element was
encountered where prohibited by the instrument.
-200,"Execution error". This is the generic syntax error for the
instrument when it cannot detect more specific errors. Execution
error as defined in IEEE-488.2 has occurred.
-221,"Setting conflict". Two conflicting parameters were received
which cannot be
executed without generating an error. An offset
value which is outside the amplitude level window may have been
sent.
-222,"Data out of range". Parameter data which followed a specific
header could not be used because its value is outside the valid
range defined by the synthesizer.
224,"Illegal parameter value". A discrete parameter was received
which was not a valid choice for the command. An invalid
parameter choice may have been used.
-300,"Device-specific-error". This is the generic device-dependent
error for the instrument when it cannot detect more specific errors.
A device- specific error as defined in IEEE-488.2 has occurred.
-311,"Memory error". Indicates that an error was detected in the
instrument’s memory.
-350,"Too many errors". The error queue is full because more than
30 errors have occurred. No additional errors are stored until the
errors from the queue are removed. The error queue is cleared
when power has been shut off, or after a *CLS command has been
executed.
-410,"Query INTERRUPTED". A command was received which
sends data to the output buffer, but the output buffer contained data
from a previous command (the previous data is not overwritten).
The output buffer is cleared when power is shut off or after a device
clear has been executed.
Device-Specific
Commands
The Model 3152 conforms to the 1993.0 version of the SCPI
standard. Some of the commands used are not included in the
1993.0 version. However, these commands are designed with the
SCPI standard in mind and they follow all of the command syntax
rules defined by the standard. Table 4-1 lists all device-specific
commands that were designed specifically for the Model 3152 as
not confirmed SCPI 1993.0 commands.
Summary of Contents for 3152
Page 16: ...Getting Started 1 7 Figure 1 1 Segment 1 Sin x x Waveform Figure 1 2 Segment 2 Sine Waveform...
Page 25: ...Configuring The Instrument 2 6 This page was intentionally left blank...
Page 63: ...Using The Instrument 3 38 This page was intentionally left blank...
Page 80: ...SCPI Command Reference 4 17 Figure 4 1 SCPI Status Registers...
Page 121: ...Specifications A 12 This page was intentionally left blank...