Using The Instrument 3-30
Trigger Signal
Figure 3-7 Sequenced Waveforms - Triggered Advance Mode
Triggered Sequence
Advance Commands
Placing the Model 3152 in Triggered Sequence Advance mode is
done in Triggered mode only. First, prepare the sequence of
waveforms using the commands that were explained before.
Second, place the instrument in Triggered mode using the
INIT:CONT OFF command. To place the Model 3152 in Triggered
Sequence Advance mode, use the following command:
SEQuence:ADVance {AUTO | TRIGger}
AUTO specifies the normal continuous advance and TRIGger
places the instrument in Triggered Sequence Advance mode.
The query:
SEQuence:ADVance?
queries Triggered Sequence Advance mode and returns AUTO or
TRIG.