8.6 Services supply
The services of PJ5KPS are supplied at 220V through a dedicated transformer.
Between the services, are included the microcontroller cards of RF modules, those
of the combiner and power supply and the control unit.
Supplying the services of the PJ5KPS with an UPS (Uninterruptable Power Supply),
the machine also in case of absence of mains power can be managed, naturally
limitedly to the functions available (for example configuration or interrogation of the
alarms registry). The normal configuration of the machine previews that the services
are directly supply through the connection to the electrical mains of the machine, in
order to insert an UPS is sufficient put it between the VDE on the roof, after have
removed the bridge that comes supplied of series.
1
ON
2
3
4
5
6
Module
Address 8
1
ON
2
3
4
5
6
Module
Address 9
1
ON
2
3
4
5
6
Module
Address 10
1
ON
2
3
4
5
6
Module
Address 11
1
ON
2
3
4
5
6
Module
Address 12
1
ON
2
3
4
5
6
Module
Address 13
1
ON
2
3
4
5
6
Module
Address 14
1
ON
2
3
4
5
6
Module
Address 15
1
ON
2
3
4
5
6
Module
Address 16
1
ON
2
3
4
5
6
Module
Address 17
Figura 8-7
Addresses regulation of RF modules
The address assigned to the module is mailed by a dip-switch on the interface board.
In figure 8-7 are brought back the configurations assigned to the different settings.
The RF module 1 (that more to left looking at the machine) have address 8, the 2 has
address 9 and so on until at 17. The other addresses are reserved for future uses.
Summary of Contents for PJ5KPS
Page 1: ...PJ5KPS User Technical Manual Manifactured by Italy ...
Page 4: ...This page intentionally left blank ...
Page 6: ...PJ5KPS ii User Technical Manual Rev 1 5 08 02 06 This page was intentionally left blank ...
Page 86: ...PJ5KPS 80 80 User Technical Manual Rev 1 5 08 02 06 This page was intentionally left blank ...