PJ5KPS
40 / 80
User & Technical Manual
Rev. 1.5 - 08/02/06
JP4/7
In
LOW PWR
Corresponds to the REDUCED POWER button of the control unit
JP4/8
In
AUDIO ALARM EXC. 1
Audio alarm of exciter 1. This input, when active, indicates an alarm
on exciter 1. If the PJ5KPS is in automatic changeover modality, if
the exciter 1 is on air and if this signal remains active for a time lag
equivalent to the time setted in the Settings menu at line Exc. Wait
time, the changeover procedure between the exciters will be started.
JP4/9
In
AUDIO ALARM EXC. 2
Same as AUDIO ALARM EXC. 1 for exciter 2.
JP4/10 /
GND
Grounding contact.
JP8/1
In
ALARM RESET
Corresponds to the ALARM RESET button on the control unit
JP8/2
In
RESRV. 1
Reserve 1 input. When this input is active, the failure is registered by
the software in the Alarms menu. For example it can be connected to
a switch that indicates that the door of the station is open or to a
sensor of a power reserve of an electric generator. In this way, by
consulting the menus of the unit, it is possible to trace the moment at
which (time and date) the failure occured.
JP8/3
In
RESRV. 2
Same as JP8/2
JP8/4
In
RESRV. 3
Same as JP8/2
JP8/5
In
RESRV. 4
Same as JP8/2
JP8/6
In
EXCITER CHANGEOVER CMD
This comand launches the changeover procedure between the
exciters. It has the same function as when you press the OK button
when selecting line On air exciter in the menu Exciters. In order to
launch the changeover between the exciters through this comand, the
manual changeover modality should be formerly selected through the
correspondent button on the control unit or through the JP8/7 jumper,
having however the unit in "Remote" modality.
JP8/7
In
EXCITER CHANGEOVER
Corresponds to ther EXCITER CHANGEOVER button of the control
unit
JP8/8
/
GND
Ground
JP16/1 Out
+12V dc
Power source. A maximum of 100 mA can be absorbed between this
jumper and JP16/2. This power source can be used if the user wants
to enter the comands following a positive logic (high voltage - active
comand)
JP16/2 OUT
+12V dc
Same as JP16/1
JP16/3 /
GND
Ground
JP16/4 /
GND
Ground
JP22/1 I/O
TX/RX +
Bus RS 485. Please note that this serial port is operational only when
the unit is in "Remote" modality.
JP22/2 I/O
TX/RX -
Bus RS 485
JP22/3 /
LINE TRM
Line termination for bus RS 485
JP22/4 /
LINE TRM
Line termination for bus RS 485
JP48/1 /
GND
Ground
JP48/2 /
GND
Ground
JP48/3 Out
FWD PWR
Forward power. Analogical output, 3.9V for 5000W
JP48/4 Out
RFL PWR
Reflect power. Analogical output, 3.9V for 1200W
JP48/5 Out
OUT AIR TEMP
Temperature of the air at the output of the chimney. Analogical output,
0V for -50°C, 3.9V for 100°C
JP48/6 Out
V BUS
Voltage at the output of the transformer/rectifier.Analogical output,
3.9V for 80V, 0V for 0V.
JP48/7 Out
EFF.
General efficiency. Analogical output, 3.9V for 100%, 0V for 0%.
JP48/8 Out
OUT DAC 6
Reserved for future applications.
JP12/1 Out
CMN MUTE 1
Common contact MUTE 1 (see JP12/2).