PJ5KPS
51 / 80
User & Technical Manual
Rev. 1.5 - 08/02/06
Code
Meaning
Control Unit
E.Intl
The external interlock is active
A.Intl
The auxiliary interlock is active
Audio-1
The Audio alarm of exciter 1 is active
Audio-2
The Audio alarm of exciter 2 is active
Ris-1
The RESERVE 1 input is active
Ris-2
The RESERVE 2 input is active
Ris-3
The RESERVE 3 input is active
Ris-4
The RESERVE 3 input is active
Mute Flt
"Mute fault”: the mute commands (i.e. the interlock commands for the
exciters) are not working, they are not connected or the connection is
wrong
Xchg Exc
A changeover of the exciters has been performed
Cfg. N+1
The machine is in Fault status because two changeover attempts have
been performed (N+1 configuration)
Power Supply
T1 -
The power supply carriage 1 is overheated
F1 -
One of the fuses or of the interlocks of the power supply carriage 1 is
blown or not closed
Tmp.
The air inlet temperature is too high
W-T2
The power supply carriage 2 is overheated
T1 W-T2
The power supply carriage 1 and 2 are overheated
F1 W-T2
One of the fuses or interlocks of carriage 1 is blown or not closed, the
power supply carriage 2 is overheated
Prs
The air pressure generated by the blower is not sufficient
F-F2
One of the fuses or of the interlocks of the power supply carriage 2 is
blown or not closed
T1 F-F2
One of the fuses or interlocks of carriage 2 is blown or not closed, the
power supply carriage 1 is overheated
F1 F-F2
One of the fuses or of the interlocks of both the power supply carriages
1 and 2 are blown or not closed
Mains
The AC power supply is out of its voltage range, or the phase sequence
is not correct
C.B. Blw
The circuit breaker of the blower blocked it
Fuse
One of the fuses or of the interlocks of the power supply is blown or
open
O.Tmp.
The power supply is overheated
Combiner .
Fwd
Forward power above its limit
Rfl
Reflected power above its limit
O.dvr In
Overdrive (main exciter)
O.dvr Ld
Too much power dissipated on the internal dummy load (stand by
exciter)
Unbal
Unbalancement power above its limit
Rej.l.T.
Overheating of the unbalancement (rejection) load resistors
Exhaust
Exhaust overheating
SWR
SWR above its limit
O.Tmp.
Internal overheating
R.F. Units
Fwd
Forward power above its limit
Rfl
Reflected power above its limit
In
Input power above its limit
Tmp.
Overheat of the RF module
Drv. I
Driver current above its limit
Mos 1 I
Current of the MOS module 1
Mos 2 I
Current of the MOS module 2
Mos 3 I
Current of the MOS module 3
Mos 4 I
Current of the MOS module 4
Eff.
Efficiency too low
Fuse
Module’s fuse broken
O.Tmp.
Overheating ov the module’s heatsink