LCC/LGA Module Series
Module Secondary SMT User Guide
Module_Secondary_SMT_User_Guide 14 / 25
5. The yellow block in the very center should
be kept intact.
UG95/UG96/
BG96/BG95
1. The stencil thickness of the area for the
module should be partly stepped-up to
0.13-0.15mm.
2. For pads on four sides:
The aperture for each single pad should be
centered with area reduced to 75%-85%.
And the shape should be rectangle with
round chamfers.
3. For square pads in the center:
The aperture for each single pad should be
designed into round and centered with area
reduced to 70%.
EG91/EG95
1. The stencil thickness of the area for the
module should be partly stepped-up to
0.13-0.15mm.
2. For pads on four sides:
The aperture for each single pad should be
centered with area reduced to 75%-85%.
And the shape should be rectangle with
round chamfers.
3. For square pads in the center:
The aperture for each single pad should be
designed into round and centered with area
reduced to 70%.
4. For pads at four corners:
The stencil aperture should be designed into
diagonal-patterned lines with 60% area of
the corresponding pad.
EG06/EG12
1. The stencil thickness of the area for the
module should be partly stepped-up to
0.13-0.15mm.
2. For pads on four sides:
The aperture for each single pad should be
centered with area reduced to 75%-85%.
And the shape should be rectangle with
round chamfers.
3. For round pads in the center:
The aperture should be centered with area
reduced to 70%. And the shape should be
round.
4. For pads at four corners: