background image

3.5  We typically site the standalone tap  
 

on the right hand side of the sink with  

 

the spout farthest away (at the back)  

 

from the user or to the back of the  

 

sink in a front to back orientation.  

 

Before you start cutting ensure that  

 

you have set up a jig or a template  

 

device to prevent the drill bit moving  

 

when you cut. 

3.6  If installing the integrated drip tray  
 

(QST-D) locate it centre of worktop,  

 

with controls to the right-hand side.

3.7  Once the hole(s) is prepared,    
 

remove any rough edges or bits of  

 

wood and place the tap carefully  

 

into the hole ensuring that the    

 

comms cable is dropped into the  

 

hole 

fi

rst to prevent damage. 

3.8  Run a bead of silicone around the  
 

edge of the holes or around the  

 

edge of the tap base unit and    

 

carefully place the SmartTap into the  

 

worksurface ensuring that the    

 

comms cable is hanging free    

 

underneath the worksurface. 

3.9  Using the 

fi

xing nut (and washer if  

 

required) provided gently tighten to  

 

underside of the worksurface to   

 

prevent the tap base (or drip tray)  

 

from moving. Once secure remove  

 

any excess silicon using a wet 

fi

nger  

 

to run around the edges pushing  

 

into the corners to create a smooth  

 

fi

nish.

————————————————————

THE COMMS CABLE CONNECTS 
INTO THE BACK-LEFT SIDE OF 
THE QST553-B. IT’S ESSENTIAL 
THAT THE QST553 IS LOCATED 
CLOSE TO THIS CABLE WITHOUT 
CAUSING IT TO STRETCH.

————————————————————

————————————————————
#4 INSTALLING THE TYPE AA (AIRGAP) 
DRAIN 

————————————————————
This device prevents reverse 
contamination into the boiling water from 
the drain.
4.1  Open the drain off kit and type AA  
 

connection found in the installation  

 

kit. Be careful not to lose any parts.  

 

Locate a suitable position on a   

 

trapped upstand (above the water  

 

trap) 

4.2  Place the O-ring in the recess    
 

around where the blade and place  

 

saddle clamp in a position where  

 

you can access the cutting device. 

4.3  Fix in place and connect the elbow,  
 

check-valve and 

fi

nally the AA    

 

airgap 

fi

tting and check it 

fi

ts. The  

 

top of the AA airgap should be at  

 

least 6” below the worksurface to  

 

ensure a fall when it is connected to  

 

the VenturiT™ onto the SmartTap™  

 

boiling pipe approx. 4-6” below the  

 

worksurface (this comes later).

4.4  When you are happy that the parts  
 

all 

fi

t and the airgap 

fi

tting is 

fi

xed  

 

pointing directly upwards, remove  

 

components and use the piercing  

 

blade or a drill to cut through the  

 

waste pipe. This part connects to the  

 

internal thread on the saddle clamp.  

 

Once cut, remove this cutting    

 

device completely and discard.

4.5  Now assemble the drain off kit with  
 

the elbow, check valve and AA   

 

fi

tting tightening all the collars to  

 

create a 

fi

rm 

fi

x. The check valve  

 

and the airgap create 2 different  

 

forms of back 

fl

ow prevention.   

I N S TA L L AT I O N

Summary of Contents for SmartTap

Page 1: ...BOILING CHILLED SPARKLING tT Collection INSTALLATION GUIDE...

Page 2: ...r 45psi Max recommended operating pressure 4Bar 60psi 1 2 Drainage Trapped upstand washing machine type Ideally located back left hand side of upboard so that it doesn t sterilise the floor space of t...

Page 3: ...E TYPICAL INSTALL QUATREAU SMARTTAP WITH DRIP TRAY Shown here with tap over adjacent cupboard for clarity When installing the tap will sit above the equipment Shown here with tap over adjacent cupboar...

Page 4: ...ntil ready to install 2 6 Open and inspect the chiller carbonator leave in its base until ready to install 3 INSTALLING THE QUATREAU SMARTTAP 3 1 NOTE THAT THE TAP MUST BE SITED ABOVE OR ADJACENT TO T...

Page 5: ...F THE QST553 B IT S ESSENTIAL THAT THE QST553 IS LOCATED CLOSE TO THIS CABLE WITHOUT CAUSING IT TO STRETCH 4 INSTALLING THE TYPE AA AIRGAP DRAIN This device prevents reverse contamination into the boi...

Page 6: ...t the John Guest 1 2 1 4 reducer from the installation kit to the cold isolation valve 6 2 Connect the blue tube found in the installation kit to this connection on the mains supply push in firmly the...

Page 7: ...60psi at all times You may need to add a pump to ensure the optimum psi is supplied to the Quatreau system During commissioning use only mains water then convert to RO once the system has been set up...

Page 8: ...4Bar 60psi CO2 CAPACITY CS20 20ltrs h at 4C NAME OF INSTALLING ENGINEER INSTALLATION DATE INSTALLATION NOTES Mains cold water pressure psi Flow rate from mains supply ltr min Hardness of mains cold wa...

Page 9: ...lution approx Refit the housing to the system and activate the water supply Run the water through the boiling chilled and sparkling function until you can smell chlorine in the water Isolate water run...