IMPORTANT INFORMATION

TECHNICAL DETAIL 

QUATREAU 553-B 

QUATREAU CS20 CHILLER CARBONATOR

POWER REQUIREMENTS  

1 x 15Amp socket 

1 x 15Amp socket

(RCD Protected) 

VOLTAGE 

110V 

110V

WATTAGE 
Max consumption 

1.5KW 

200W

Standby consumption 

80W  

0W

START UP TIME 

10 minutes 

10 minutes

MAX WORKING PRESSURE 

4Bar / 60psi

 

4Bar / 60psi

CO2 CAPACITY 

 

CS20 = 20ltrs/h at 4C

NAME OF INSTALLING ENGINEER 

..................................................................

INSTALLATION DATE 

..................................................................

INSTALLATION NOTES  
Mains cold water pressure?                                                  .................................................. 

psi

Flow rate from mains supply ?                                               ..................................................  ltr/min

Hardness of mains cold water? 

.................................................. 

gpg

If hardness is above 10gpg has a OneStop Plus™ 
scale reduction 

fi

lter been installed?  

.................................................. 

y/n

For further details visit

https://www.globalwatersolutions.com/
products/water-treatment/onestop-plus/

Has the type AA airgap drain off device been installed
in accordance with the instructions? 

.................................................. 

y/n

 

I N S TA L L AT I O N

Summary of Contents for SmartTap

Page 1: ...BOILING CHILLED SPARKLING tT Collection INSTALLATION GUIDE...

Page 2: ...r 45psi Max recommended operating pressure 4Bar 60psi 1 2 Drainage Trapped upstand washing machine type Ideally located back left hand side of upboard so that it doesn t sterilise the floor space of t...

Page 3: ...E TYPICAL INSTALL QUATREAU SMARTTAP WITH DRIP TRAY Shown here with tap over adjacent cupboard for clarity When installing the tap will sit above the equipment Shown here with tap over adjacent cupboar...

Page 4: ...ntil ready to install 2 6 Open and inspect the chiller carbonator leave in its base until ready to install 3 INSTALLING THE QUATREAU SMARTTAP 3 1 NOTE THAT THE TAP MUST BE SITED ABOVE OR ADJACENT TO T...

Page 5: ...F THE QST553 B IT S ESSENTIAL THAT THE QST553 IS LOCATED CLOSE TO THIS CABLE WITHOUT CAUSING IT TO STRETCH 4 INSTALLING THE TYPE AA AIRGAP DRAIN This device prevents reverse contamination into the boi...

Page 6: ...t the John Guest 1 2 1 4 reducer from the installation kit to the cold isolation valve 6 2 Connect the blue tube found in the installation kit to this connection on the mains supply push in firmly the...

Page 7: ...60psi at all times You may need to add a pump to ensure the optimum psi is supplied to the Quatreau system During commissioning use only mains water then convert to RO once the system has been set up...

Page 8: ...4Bar 60psi CO2 CAPACITY CS20 20ltrs h at 4C NAME OF INSTALLING ENGINEER INSTALLATION DATE INSTALLATION NOTES Mains cold water pressure psi Flow rate from mains supply ltr min Hardness of mains cold wa...

Page 9: ...lution approx Refit the housing to the system and activate the water supply Run the water through the boiling chilled and sparkling function until you can smell chlorine in the water Isolate water run...

Reviews: