background image

————————————————————
#2 UNPACKING YOUR EQUIPMENT
————————————————————

2.1 

If your system’s protective packing  

 

is damaged upon delivery you   

 

should photograph the damage  

 

and remove the contents for  

 

 

inspection before signing the    

 

delivery note. There will 2 or 3 boxes  

 

depending on the model you have  

 

purchased.

2.1.1  Quatreau SmartTap™ (faucet)

2.1.2  Quatreau Boiler

2.1.3  Quatreau Chiller / Chiller Carbonator  

2.2  Open and inspect the Quatreau  
 

SmartTap™ to inspect the  

 

 

components and installation kit. Use  

 

the packaging to prevent damaged  

 

until ready to 

fi

t to work surface.

2.3  Open the top of the Quatreau    
 

Boiler (QST553-B) box and remove  

 

the top protective layer. You will see  

 

two protruding opaque stems, be  

 

careful not to damage these outlets. 

2.4  Cut down each side of the box   
 

to reveal the system so that you   

 

don’t have to lift it out of the box. The  

 

boiler will be installed on the  

 

 

right-hand side of the cupboard  

 

after you’ve installed the SmartTap™.  

 

This item weighs 44lbs. Please take  

 

care when moving or lifting, the  

 

sides and corners are hard and will  

 

damage furniture if knocked.

2.5  Leave the system on the protective  
 

packaging until ready to install. 

2.6  Open and inspect the chiller  

 

 

carbonator, leave in its base until  

 

ready to install.

————————————————————

————————————————————
#3 INSTALLING THE 

QUATREAU 

SMARTTAP™

————————————————————

3.1  NOTE THAT THE TAP MUST BE  
 

SITED ABOVE OR  ADJACENT  

 

TO THE QST553-B (BOILER  

 

CONTROL UNIT), CLOSE   

 

ENOUGH SO THAT THE    

 

COMMUNICATION CABLE  

 

FROM THE SMARTTAP™ IS  

 

NOT STRETCHED WHEN IT  

 

PLUGS INTO THE BACK LEFT  

 

SIDE OF THE BOILER.

————————————————————

3.2

 

THE QUATREAU SMARTTAP™  will come  

 

as a stand-alone tap or integrated  

 

into a drip-tray. With the relevant  

 

cutting template enclosed with your  

 

product choose the most suitable  

 

position for the tap.

3.3  Depending upon the surface you will  
 

need special cutting equipment. For  

 

granite or marble a diamond tipped  

 

core bit will be required. For wood or  

 

MDF or polymer type surface a   

 

wood bit will normally be adequate.  

 

Always check with the worksurface  

 

manufacturer and ask what type of  

 

bit can be used. 

3.4  Decide where the tap is going to sit.  
 

Note that the control panel on the  

 

drip tray is on the right-hand side of  

 

the tap. Ensure that the location you  

 

choose is suitable and that you can  

 

reach the controls without needing  

 

to stretch whilst ensuring that the user  

 

will not have to reach through the  

 

stream of water to operate the tap.  

 

Your kitchen design will of course  

 

dictate where you can install it    

 

safely. 

I N S TA L L AT I O N

Summary of Contents for SmartTap

Page 1: ...BOILING CHILLED SPARKLING tT Collection INSTALLATION GUIDE...

Page 2: ...r 45psi Max recommended operating pressure 4Bar 60psi 1 2 Drainage Trapped upstand washing machine type Ideally located back left hand side of upboard so that it doesn t sterilise the floor space of t...

Page 3: ...E TYPICAL INSTALL QUATREAU SMARTTAP WITH DRIP TRAY Shown here with tap over adjacent cupboard for clarity When installing the tap will sit above the equipment Shown here with tap over adjacent cupboar...

Page 4: ...ntil ready to install 2 6 Open and inspect the chiller carbonator leave in its base until ready to install 3 INSTALLING THE QUATREAU SMARTTAP 3 1 NOTE THAT THE TAP MUST BE SITED ABOVE OR ADJACENT TO T...

Page 5: ...F THE QST553 B IT S ESSENTIAL THAT THE QST553 IS LOCATED CLOSE TO THIS CABLE WITHOUT CAUSING IT TO STRETCH 4 INSTALLING THE TYPE AA AIRGAP DRAIN This device prevents reverse contamination into the boi...

Page 6: ...t the John Guest 1 2 1 4 reducer from the installation kit to the cold isolation valve 6 2 Connect the blue tube found in the installation kit to this connection on the mains supply push in firmly the...

Page 7: ...60psi at all times You may need to add a pump to ensure the optimum psi is supplied to the Quatreau system During commissioning use only mains water then convert to RO once the system has been set up...

Page 8: ...4Bar 60psi CO2 CAPACITY CS20 20ltrs h at 4C NAME OF INSTALLING ENGINEER INSTALLATION DATE INSTALLATION NOTES Mains cold water pressure psi Flow rate from mains supply ltr min Hardness of mains cold wa...

Page 9: ...lution approx Refit the housing to the system and activate the water supply Run the water through the boiling chilled and sparkling function until you can smell chlorine in the water Isolate water run...