Page 3: ...20 280 cm Wire 2x 0 75 mm2 350 cm for HUUM furnace temperature sensor 4 Set 4 self extinguishing protective pipe phi 20 330 cm wire 2x 0 75 2 400 cm for LED lighting left side 5 Wire 5x 4 0 mm2 200 c...

Page 4: ...5 mm 7 pcs Screws for the base of the SOS switch phi 3 8 length 25 mm 4 pcs Screws for temperature sensor HUUM fi 2 8 length 15 mm 2 pcs Screws for HUUM controller phi 3 length 30 mm 2 pcs 16 Clamping...

Page 5: ...uare 7 Wood hole saw 65 mm 8 Cordless drill 9 Chisel 10 Drill bits 2 5 mm 5 mm 10 mm 11 Phillips screwdriver 12 Flathead screwdriver 13 Paper tape 14 Soldering compound 15 Transformer soldering iron 1...

Page 6: ...2x 1 50 mm2 470 cm for the LED lighting supply 2 Arrange and tape the wires as shown in the picture then wrap them all around this will make it easier to lead them through the protective pipe without...

Page 7: ...er core from the wire using pliers 8 Use a wire stripper to remove the insulation from the wires then use a crimping tool to fix the 4 mm2 wire ends on both sides 9 Insert wire 6 into the protective p...

Page 8: ...Solder the ends of the wire at the soldering points using a precision soldering iron Add the wire with the black line to the 13 Repeat the operation for the second LED strip II ARMING AND INSTALLATION...

Page 9: ...harness 1 Protective pipe with wire 3 Furnace power wire 5 NOTE The wires should be routed out of the protective pipes in the box with an allowance as shown in the picture below Harness 1 50 cm count...

Page 10: ...ng hole connecting the protective pipe 2 using a torsion gland 4 Feed wire 5 through the hole in the structure leaving an allowance as shown in the picture below 5 Remove the protective pipe 1A and le...

Page 11: ...allation_v5 1_06092021 10 6 Feed the protective pipe with harness 1 through the vias in the structure as illustrated below 7 Insert protective pipe 1A leaving the black wire from the harness to the SO...

Page 12: ...he structure and lead it outside then put the pipe through the grommets in the structure and lead it up to the top of the sauna 2 Attach the clamp and use it to secure the protective pipe 3 3 Make a h...

Page 13: ...loop on it to prevent it from slipping out during the installation of the wool and the external facade IV LAYING OF LED LIGHT INSTALLATION 4 1 Pull the protective pipe 4 inside the sauna structure un...

Page 14: ...gree angle Then widen it with a phi 10 drill bit NOTE The hole must be drilled precisely at a height of 44 cm from the bench seat and 14 cm from the edge of the door opening it will be covered by the...

Page 15: ...LLATION OF SAUCE BOX SWITCH INSTALLATION 1 Measure 13 cm from the door frame and 13 cm from the underside of the bench Drill a hole for the SOS button box using a hole saw 2 Insert the box into the ho...

Page 16: ...tightened 4 Tack the ends onto the cables and screw to the switch NOTE The wires should be screwed to the side marked in red poles 1 and 2 5 Drill four holes with a 2 5 mm drill bit so that the base i...

Page 17: ...location of the hole for the box so that it is in the middle of the second vertical paneling board IMPORTANT at a height of 56 cm from the underside of the bench Pre drill then use a chisel to deflect...

Page 18: ...he protective pipe 1A and 4 VII DRILLING THE HOLES FOR WIRE 8 OF THE DOOR OPENING DETECTOR HUUM 1 Make a hole with a drill phi 6 mm in the door frame at a height of 72 cm from the threshold of the doo...

Page 19: ...e from the harness and solder them together using a transformer soldering iron 2 Using a cigarette lighter secure the wire connections 3 Glue the ends of the LED strip on both sides using universal si...

Page 20: ...he above steps for the left side connecting to wire 7 IX PREPARATION AND INSTALLATION OF THE ALARM SIREN 1 Cut a 6 cm wide piece from the phi 110 pipe Then make an undercut for the siren wire 2 Make a...

Page 21: ...4 mm length 15 mm 5 Fit double WAGO connectors on each wire 6 Fit 0 75 mm2 cable lugs on wire 3 Then connect the wires from the siren to the harness with WAGO connectors according to the colors in the...

Page 22: ...the wires to make it easier to attach them to the sensor Using a small screwdriver screw them onto the sensor mounts 2 Drill a hole using a drill phi 2 5 then screw in the bottom mounting screw Slide...

Page 23: ...1 2x 0 75 mm2 then solder it to the sensor wire 8 routed through the mounting hole of the box to the door frame 2 Tuck the wire into the mounting hole on the box NOTE The wire should be tucked outside...

Page 24: ...from which the 8 wire protrudes and lubricate the end of the sensor with universal mounting silicone spreading it over the sensor Press it into the mounting hole and clean off any excess silicone 6 S...

Page 25: ...tor 2 ash wire Connector 3 green yellow wire Connector 4 black 2 Check the attachment of the wires to the sensor and tighten the fixing screws if necessary Secure the contacts with PVB varnish 3 When...

Page 26: ...AND MOUNTING OF THE LED LIGHT SWITCH 1 Attach the cable lugs to a Power wire from harness 1 2x 1 5 mm2 b LED wire left 4 c LED wire right 7 2 Use WAGO connector 3 to connect the wires 3 Connect the ph...

Page 27: ...es in the base of the switch 6 Pass the switch with the connected LED light wires through the hole in the base 7 Evenly fit the base to the paneling and drill the screw holes using the same drill bit...

Page 28: ...its place according to the pictures below B Connection of SOS button installation 1 Identify the wire from harness 1 2x 0 75 mm2 to the SOS switch To do this switch on the SOS switch and check with a...

Page 29: ...rom harness 1 with cable lugs 2 Find the wire marked LED in the box and insert the wires in its place D Preparation of the HUMM control unit and its connection to the installation 1 Remove the screws...

Page 30: ...5 1_06092021 29 2 Assemble the torsion glands and rubber glands as shown in the photo 3 Remove the two screws so that there is clearance for the wire Tighten the others including the silver mounting s...

Page 31: ...om harness 1 to the door opening sensor through the small gland at the bottom c Wire from harness 1 to the Wi Fi controller via the small choke from above d Wire from harness 3 to temperature sensor t...

Page 32: ...wire 5 7 Connect the temperature sensor wire T1 and T2 and the door opening wire O1 and O2 according to the diagram in the photo 8 Connect the wire to the Wi Fi controller according to the diagram in...

Page 33: ...place the cover and fasten it with the screws provided Write the sauna s serial number on the cover with a marker and take a photo of the label Send the photo to radoslaw wojcik suncubesauna com E Con...

Page 34: ...21 33 2 Connect the phase wires to the contactor in place of the wires you removed remember to insert the black wire from the photo above 3 Using the 400 V junction block connect the wires from the bo...

Page 35: ...on XIV points A B and C XV FINAL TEST OF THE ELECTRICAL INSTALLATION CONNECTIONS 1 Screw on the furnace wire terminals 5 for voltage test purposes 2 Connect the 400 V power test wire to the wiring in...

Page 36: ...6 Heat the air with a lighter around the HUMM temperature sensor to verify its operation The temperature shown on the display should increase when heated 7 Check the operation of the door closure sen...

Page 37: ...hase on the three wires brown grey black of harness 5 using a tester 10 Disconnect the power supply to the 400 V mains cable 11 Remove the cube from the installation 12 Close the box and turn the cove...