Chapter 3: FRU Removal and Replacement Procedures
Replacing the Node Integrated Storage Controller
Quantum DXi6900 G2 Field Service Manual
108
Figure 62:
Checking Integrated Storage Controller Status
Removing a Failed Integrated Storage Controller
To remove the integrated storage controller from the DXi6900 G2 Node:
Turning Off the DXi6900 G2 on page 23
).
Opening and Closing the Node on page 64
).
3. Remove the expansion card riser 1 (see
Replacing an Expansion Card in Riser 1 on page 98
).
4. Loosen the screws that secure the integrated controller cable to the integrated storage-controller card
connector on the system board (see
).
5. Lift the integrated storage controller cable out.
6. Angle the card so that the other end of the card disengages from the storage controller card holder on
the system board.
7. Lift the card out of the chassis.