![Quantum DXi6900 Field Service Manual Download Page 32](http://html1.mh-extra.com/html/quantum/dxi6900/dxi6900_field-service-manual_3777791032.webp)
Chapter 1: Basic Operations
DXi6900 G2 Array and Expansion Modules
Quantum DXi6900 G2 Field Service Manual
19
Item
Button/LEDs
Description
4
SAS host/expansion activity (green)
Both Off
- cable unplugged. Fault Off and Activity On -
all links operating.
Fault On and Activity Off
- at least one link active and
at least one link fault.
5
Battery fault (amber)
On
- battery has failed.
Off
- battery operating as normal.
6
Battery charging (green)
Blinking
- battery is charging.
On
- battery is fully charged.
Off
- battery fault or no battery
7
Service action allowed (blue)
Solid
- safe for Quantum field service. to remove
controller from slot.
8
Service action required (amber)
Solid
- controller has failed and requires attention. Fault
light will be on during power up and will turn off after
self-test sequence completes.
9
Cache active (green)
Solid
- unwritten data is stored in cache.
Blinking
- during AC power failure, cache offload is
occurring.
10
Seven segment display (green)
Displays tray ID and error code. (Displays
99
when the
Array module is operating normally.)
11
USB
Not used.
12
Mini USB
Not used.
13
Reset switch
Not used.
14
Standby power (green)
Solid
- main DC power is off and 5V standby power is
on.
15
DC enabled (green)
Solid
- DC power rails are within specified limits.
16
Service action allowed (blue)
Solid
- safe for Quantum field service. to remove power
supply from slot.
17
Service action required (amber)
Solid
- power supply has failed and requires attention.
18
AC enabled (green)
Solid
- power is being applied to the power supply and
the power switch is on.
19
Power switch
Module power switch.