6
Quadra-Fire • TOPAZ-MBK-IPI, TOPAZD-PMH-IPI, TOPAZD-MBK-IPI, TOPAZD-CSB-IPI Owner’s Manual • 2341-981_R4 • 10/15
C. BTU Specifications
This product is listed to ANSI standards for “Vented Gas
stove Heaters” and applicable sections of “Gas Burning
Heating Appliances for Manufactured Homes and
Recreational Vehicles”, and “Gas Fired Appliances for Use
at High Altitudes”.
NOTICE:
This installation must conform with local codes. In
the absence of local codes you must comply with the National
Fuel Gas Code, ANSI Z223.1-latest edition in the U.S.A. and
the CAN/CGA B149 Installation Codes in Canada.
A. Appliance Certification
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemental
room heat or as a decorative appliance. It should not be fac
-
tored as primary heat in residential heating calculations.
2
Product Specific Information
B. Glass Specifications (Ceramic)
This appliance is equipped with 5 mm ceramic glass.
Replace glass only with 5 mm ceramic glass. Please contact
your dealer for replacement glass.
Installation and service of this appliance should be
performed by qualified personnel. Hearth & Home
Technologies suggests NFI certified or factory trained
professionals, or technicians supervised by an NFI
certified professional (www.nficertified.org).
MODELS:
TOPAZ-MBK-IPI, TOPAZD-PMH-IPI, TOPAZD-MBK-
IPI, TOPAZD-CSB-IPI
LABORATORY:
Underwriters Laboratories, Inc. (UL)
TYPE:
Direct Vent Heater
STANDARD:
ANSI Z21.88-2014/CSA 2.33-2014
Models
(U.S. or Canada)
Maximum
Input
BTU/h
Minimum
Input
BTU/h
Orifice
Size
(DMS)
AFUE
State
Steady
Efficiency %
P4 %
TOPAZ-MBK-IPI
TOPAZ
D-PMH-IPI
TOPAZD-MBK-IPI
TOPAZD-CSB-IPI
(NG)
(0-2000 FT)
37,000 26,000
32
68.6%
69%
70%
TOPAZ-MBK-IPI
TOPAZ
D-PMH-IPI
TOPAZD-MBK-IPI
TOPAZD-CSB-IPI
(LP)
(0-2000 FT)
34,000 26,000
50
69.4%
69%
69%