background image

5

Quadra-Fire  •  TOPAZ-MBK-IPI, TOPAZD-PMH-IPI, TOPAZD-MBK-IPI, TOPAZD-CSB-IPI Owner’s Manual  •  2341-981_R4 •  10/15

B.  Limited Lifetime Warranty

 (continued)

WARRANTY CONDITIONS:

•  This warranty only covers HHT appliances that are purchased through an HHT authorized dealer or distributor. A list of 

HHT authorized dealers is available on the HHT branded websites.

•  This warranty is only valid while the HHT appliance remains at the site of original installation.

•     This warranty is only valid in the country in which the HHT authorized dealer or distributor that sold the appliance 

resides.

•  Contact your installing dealer for warranty service. If the installing dealer is unable to provide necessary parts, contact 

the nearest HHT authorized dealer or supplier. Additional service fees may apply if you are seeking warranty service 

from a dealer other than the dealer from whom you originally purchased the product.

•  Check with your dealer in advance for any costs to you when arranging a warranty call. Travel and shipping charges 

for parts are not covered by this warranty.

This warranty is void if:

•  The appliance has been over-fired or operated in atmospheres contaminated by chlorine, fluorine, or other damaging 

chemicals. Over-firing can be identified by, but not limited to, warped plates or tubes, rust colored cast iron, bubbling, 

cracking and discoloration of steel or enamel finishes.

•  The appliance is subjected to prolonged periods of dampness or condensation.

•  There is any damage to the appliance or other components due to water or weather damage which is the result of, but 

not limited to, improper chimney or venting installation.

LIMITATIONS OF LIABILITY:

•  The owner’s exclusive remedy and HHT’s sole obligation under this warranty, under any other warranty, express or 

implied, or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified above. In no 

event will HHT be liable for any incidental or consequential damages caused by defects in the appliance. Some states 

do not allow exclusions or limitation of incidental or consequential damages, so these limitations may not apply to you. 

This warranty gives you specific rights; you may also have other rights, which vary from state to state. EXCEPT TO 

THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY 

SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE 

EXPRESSED WARRANTY SPECIFIED ABOVE.

WARRANTY EXCLUSIONS:

This warranty does not cover the following:

•  Changes in surface finishes as a result of normal use. As a heating appliance, some changes in color of interior and 

exterior surface finishes may occur. This is not a flaw and is not covered under warranty.

•  Damage to printed, plated, or enameled surfaces caused by fingerprints, accidents, misuse, scratches, melted items, 

or other external sources and residues left on the plated surfaces from the use of abrasive cleaners or polishes.

•  Repair or replacement of parts that are subject to normal wear and tear during the warranty period. These parts 

include: paint, wood, pellet and coal gaskets, firebricks, grates, flame guides, batteries and the discoloration of glass.

•  Minor expansion, contraction, or movement of certain parts causing noise. These conditions are normal and com-

plaints related to this noise are not covered by this warranty.

•  Damages resulting from: (1) failure to install, operate, or maintain the appliance in accordance with the installation 

instructions, operating instructions, and listing agent identification label furnished with the appliance; (2) failure to 

install the appliance in accordance with local building codes; (3) shipping or improper handling; (4) improper opera-

tion, abuse, misuse, continued operation with damaged, corroded or failed components, accident, or improperly/ 

incorrectly performed repairs; (5) environmental conditions, inadequate ventilation, negative pressure, or drafting 

caused by tightly sealed constructions, insufficient make-up air supply, or handling devices such as exhaust fans or 

forced air furnaces or other such causes; (6) use of fuels other than those specified in the operating instructions; (7) 

installation or use of components not supplied with the appliance or any other components not expressly authorized 

and approved by HHT; (8) modification of the appliance not expressly authorized and approved by HHT in writing; 

and/or (9) interruptions or fluctuations of electrical power supply to the appliance.

•  Non-HHT venting components, hearth components or other accessories used in conjunction with the appliance.

•  Any part of a pre-existing fireplace system in which an insert or a decorative gas appliance is installed.

•  HHT’s obligation under this warranty does not extend to the appliance’s capability to heat the desired space. Informa-

tion is provided to assist the consumer and the dealer in selecting the proper appliance for the application. Consider-

ation must be given to appliance location and configuration, environmental conditions, insulation and air tightness of 

the structure.

4021-645G   2/15 

Page 2 of 2

Summary of Contents for TOPAZ-MBK-IPI

Page 1: ...tion OWNER Retain this manual for future reference Contact your dealer with questions regarding installation operation or service DO NOT store or use gasoline or other flammable vapors and liquids in...

Page 2: ...un combustible solide This appliance must be installed in accordance with local codes if any if not follow ANSI Z223 1 in the USA or CAN CGA B149 installation codes Installer l appareil selon les code...

Page 3: ...nce Certification 6 B Glass Specifications Ceramic 6 C BTU Specifications 6 3 Important Safety and Operating Information A Appliance Safety 7 B General Operating Parts 8 C Fuel Specifications 8 D Befo...

Page 4: ...y coverage begins on the date of original purchase In the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the prod...

Page 5: ...FIED ABOVE WARRANTY EXCLUSIONS This warranty does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior su...

Page 6: ...imary heat in residential heating calculations 2 Product Specific Information B Glass Specifications Ceramic This appliance is equipped with 5 mm ceramic glass Replace glass only with 5 mm ceramic gla...

Page 7: ...rom hot surfaces Install a switch lock or a wall remote control with child protection lockout feature Keep remote controls out of reach of children Never leave children alone near a hot stove whether...

Page 8: ...in place WARNING Risk of Fire or Asphyxiation DO NOT operate stove with fixed glass assembly removed Figure 3 2 General Operating Parts GLASS ASSEMBLY SECTION 4 B FAN KIT SECTION 6 A CLEAR SPACE SECT...

Page 9: ...T operate the appliance with fixed glass assembly removed cracked or broken Replacement of the fixed glass assembly should be done by a licensed or qualified service person For use with natural gas an...

Page 10: ...lation during stove break in Some people may be sensitive to smoke and odors Smoke detectors may activate G Heat Management Heat Output This model has a variable burn rate which is controlled by the H...

Page 11: ...module damage will occur Figure 3 6 A complete wiring diagram is included in the Electrical section of the appliance Installation Manual 3 Turn the appliance on according to the instructions below fo...

Page 12: ...ion is primarily used for initial installation or power outage operation with battery backup REMOTE Position Appliance will initiate commands from an optional wired wall switch and or the wireless rem...

Page 13: ...ss Inspection Annually Qualified Service Technician Log Inspection Annually Firebox Inspection Annually Control Compartment firebox Top Annually Burner Ignition Operation Annually When properly mainta...

Page 14: ...te control operation instructions for proper calibration and setup procedure Place batteries as needed in remote transmitters and battery powered receivers Place remote control out of reach of childre...

Page 15: ...caution when cleaning these areas Screw tips that have penetrated the sheet metal are sharp and should be avoided Remove all foreign objects Verify unobstructed air circulation Figure 4 3 IPI Pilot F...

Page 16: ...ing of the paint and the burning off of any oils remaining from manufacturing If appliance has not been used for some time dust can build up and cause an odor Film on the glass This is a normal result...

Page 17: ...le Check voltage of transformer at connection to module Acceptable read ings of a good transformer are between 6 4 and 6 6 volts DC Bat tery power supply voltage must be at least 4 volts If less than...

Page 18: ...sensing rod to white sensor wire Polish flame sensing rod with fine steel wool to remove any contaminants that may have accumulated on flame sensing rod Verify continuity with a multi meter with ohms...

Page 19: ...ard and will void the warranty Remote Controls Switches After a qualified service technician has installed the remote control follow the instructions supplied with the control installed to operate you...

Page 20: ...Parts Service Parts Topaz Beginning Manufacturing Date July 2014 Ending Manufacturing Date Active R TOPAZ IPI Part number list on following page Log Set Assembly Gas Stove DV 09 15 TOPAZ MBK IPI TOPA...

Page 21: ...0040MBK Mahogany 468 0040PMH Sienna Bronze 468 0040CSB 6 Top Black 468 0010MBK Mahogany 468 0010PMH Sienna Bronze 468 0010CSB 7 Shroud Upper Fan Qty 2 req 2340 130 8 Bracket Top Mounting Qty 2 req 23...

Page 22: ...inge Pin 844 5750 Y Magnet Round SRV7000 140 Y Thumbscrew 1 4 20 X 3 4 844 5070 Plate Support 2340 110 15 Screen Assembly Solitare 466 023 Quartet 466 021 16 Refractory Assembly BRICK TOPAZ Y 17 Glass...

Page 23: ...ce parts from your dealer or distributor Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER 22 1 Heat Shield J box 2342 132 22 2 Junction Box 4021 013 Y 22 3 Elbow 3 8 Flare Male 4021 045 22 4 Val...

Page 24: ...r distributor Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER 26 1 Starting Collar 2189 002 26 2 Gasket Adaptor 460 0610 26 3 Flue Assembly 2340 025 26 4 Relief Door Guide 2340 133 26 5 Relief...

Page 25: ...0A Y Temp Sensor Limit w Bracket 107 531A Y Firescreen Quartet Front Only 844 9360 Leveling Assembly 7000 000 Mineral Wool 050 721 Ori ce NG 32 Top Vent 582 832 Y Ori ce LP 50 Top Vent 582 850 Y Ori c...

Page 26: ...________________________________________________________________ ________________________________________________________________________________ ______________________________________________________...

Reviews: