14
Quadra-Fire • TOPAZ-MBK-IPI, TOPAZD-PMH-IPI, TOPAZD-MBK-IPI, TOPAZD-CSB-IPI Owner’s Manual • 2341-981_R4 • 10/15
• Clean glass with a non-abrasive commercially available
cleaner
.
- Light deposits: Use a soft cloth with soap and water.
- Heavy deposits: Use commercial stove glass cleaner
(consult with your dealer).
• Reinstall the glass frame by reattaching the three Phillips
head fasteners. Tighten until snug. Do not overtighten.
• Reinstall front casting.
• Reinstall safety barrier
Remote Control
Frequency:
Seasonally
By:
Homeowner
Tools needed:
Replacement batteries and remote control
instructions.
• Locate remote control transmitter and receiver.
• Verify operation of remote. Refer to remote control
operation instructions for proper calibration and setup
procedure.
• Place batteries as needed in remote transmitters and
battery-powered receivers.
• Place remote control out of reach of children.
If not using your stove for an extended period of time
(summer months, vacations/trips, etc), to prevent
unintended operation:
• Remove batteries from remote controls.
• Unplug 6 volt adapter plug on IPI models.
Venting
Frequency:
Seasonally
By:
Homeowner
Tools needed:
Protective gloves and safety glasses.
• Inspect venting and termination cap for blockage or
obstruction such plants, bird nests, leaves, snow, debris,
etc.
• Verify termination cap clearance to subsequent construction
(building additions, decks, fences, or sheds).
• Inspect for corrosion or separation.
• Verify weather stripping, sealing and flashing remains
intact.
• Inspect draft shield to verify it is not damaged or missing.