background image

2

Quadra-Fire  •  TOPAZ-MBK-IPI, TOPAZD-PMH-IPI, TOPAZD-MBK-IPI, TOPAZD-CSB-IPI Owner’s Manual  •  2341-981_R4 •  10/15

Listing Label Information/Location

A. Congratulations

Congratulations on selecting a Quadra-Fire gas stove, an 

elegant and clean alternative to wood burning stoves. The 

Quadra-Fire  gas  stove  you  have  selected  is  designed  to 

provide the utmost in safety, reliability, and efficiency.

As the owner of a new stove, you’ll want to read and carefully 

follow all of the instructions contained in this owner’s manual. 

Pay special attention to all cautions and warnings.

The model information regarding your specific stove can be found on the rating 

plate usually located in the control area of the stove.

Read this manual before operating this appliance. 

Please retain this Owner’s Manual for future reference.

Read the Installation Manual before making any installation or finishing changes.

Welcome  

Brand: ________________________________________________ Model Name: ___________________________

Serial Number: __________________________________________ Date Installed: __________________________

Appliance Information:

Local Dealer Information

DEALER:

 

Fill in 

your name, address, 

phone and email 

information here and 

appliance information 

below.

Dealer Name: ________________________________________________________

Address: ____________________________________________________________

               ____________________________________________________________

Phone:   _____________________________________________________________

Email:    _____________________________________________________________

Gas and Electric 

Information

Serial Number

Type of Gas

Model Number

Not for use with solid fuel.

(

Ne doit pas entre utilise avec un combustible solide).

This appliance must be installed in accordance with local codes, if any; if not, follow ANSI Z223.1

in the USA or CAN/CGA B149 installation codes. 

(Installer l’appareil selon les codes ou reglements

locaux  ou,  en  l’absence  de  tels  reglements,  selon  les  codes  d’installation 

Type of Gas 

(Sorte De Gaz)

:

NATURAL GAS

MADE 

MADE   IN 

IN   USA

USA

Minimum 

Minimum Permissible 

Permissible 

Quadra-Fire, a brand of Hearth & Home Technologies

7571 215th Street West, Lakeville, MN 55044

Gas 

Gas Supply 

Supply for 

for Purposes 

Purposes of 

of Input 

Input Adjustment.

Adjustment.

Approved 

Approved Minimum 

Minimum 

(De 

(De Gaz) 

Gaz) 

Acceptable

Acceptable 0.0

0.0  in 

in w.c.

w.c.

(Po. 

(Po. Col. 

Col. d’eau)

d’eau)

Maximum 

Maximum Pressure 

Pressure 

(Pression)

(Pression)

  0.0

0.0  in 

in w.c.

w.c.

(Po. 

(Po. Col. 

Col. d’eau)

d’eau)

Maximum 

Maximum Manifold 

Manifold Pressure 

Pressure 

(Pression)

(Pression)

   

   0.0

0.0  in 

in w.c.

w.c.

(Po. 

(Po. Col. 

Col. d’eau)

d’eau)

Minimum 

Minimum Manifold 

Manifold Pressure 

Pressure 

(Pression)

(Pression)

   

   0.0

0.0  in 

in w.c.

w.c.

(Po. 

(Po. Col. 

Col. d’eau)

d’eau)

Model:

Model:

(Modele):

(Modele):

Serial

Serial

(Serie):

(Serie):

ANSI Z21XX-XXXX · CSA 2.XX-MXX  

XXXXXXXX

XXXXXXXX

IN 

IN CANADA

CANADA

ALTITUDE:

ALTITUDE:

0-0000 

0-0000 FT.

FT. 0000-0000FT.

0000-0000FT.

MAX. 

MAX. INPUT 

INPUT BTUH:

BTUH:

00,000

00,000

00,000

00,000

MIN. 

MIN. INPUT 

INPUT BTUH:

BTUH:

00,000

00,000

00,000

00,000

ORIFICE 

ORIFICE SIZE:

SIZE:

#XXXXX

#XXXXX

#XXXXX

#XXXXX

XXXXXXXX

XXXXXXXX

Total 

Total Electrical 

Electrical Requirements: 

Requirements: 000Vac, 

000Vac, 00Hz., less than 00 Amperes

R

This owner’s manual

 

should be retained for future reference. 

We suggest that you keep it with your other important 

documents and product manuals.

The information contained in this owner’s manual, unless 

noted otherwise, applies to all models and gas control 

systems.
Your new Quadra-Fire gas stove will give you years of durable 

use and trouble-free enjoyment. Welcome to the Quadra-Fire 

family of stove products!

Summary of Contents for TOPAZ-MBK-IPI

Page 1: ...tion OWNER Retain this manual for future reference Contact your dealer with questions regarding installation operation or service DO NOT store or use gasoline or other flammable vapors and liquids in...

Page 2: ...un combustible solide This appliance must be installed in accordance with local codes if any if not follow ANSI Z223 1 in the USA or CAN CGA B149 installation codes Installer l appareil selon les code...

Page 3: ...nce Certification 6 B Glass Specifications Ceramic 6 C BTU Specifications 6 3 Important Safety and Operating Information A Appliance Safety 7 B General Operating Parts 8 C Fuel Specifications 8 D Befo...

Page 4: ...y coverage begins on the date of original purchase In the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the prod...

Page 5: ...FIED ABOVE WARRANTY EXCLUSIONS This warranty does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior su...

Page 6: ...imary heat in residential heating calculations 2 Product Specific Information B Glass Specifications Ceramic This appliance is equipped with 5 mm ceramic glass Replace glass only with 5 mm ceramic gla...

Page 7: ...rom hot surfaces Install a switch lock or a wall remote control with child protection lockout feature Keep remote controls out of reach of children Never leave children alone near a hot stove whether...

Page 8: ...in place WARNING Risk of Fire or Asphyxiation DO NOT operate stove with fixed glass assembly removed Figure 3 2 General Operating Parts GLASS ASSEMBLY SECTION 4 B FAN KIT SECTION 6 A CLEAR SPACE SECT...

Page 9: ...T operate the appliance with fixed glass assembly removed cracked or broken Replacement of the fixed glass assembly should be done by a licensed or qualified service person For use with natural gas an...

Page 10: ...lation during stove break in Some people may be sensitive to smoke and odors Smoke detectors may activate G Heat Management Heat Output This model has a variable burn rate which is controlled by the H...

Page 11: ...module damage will occur Figure 3 6 A complete wiring diagram is included in the Electrical section of the appliance Installation Manual 3 Turn the appliance on according to the instructions below fo...

Page 12: ...ion is primarily used for initial installation or power outage operation with battery backup REMOTE Position Appliance will initiate commands from an optional wired wall switch and or the wireless rem...

Page 13: ...ss Inspection Annually Qualified Service Technician Log Inspection Annually Firebox Inspection Annually Control Compartment firebox Top Annually Burner Ignition Operation Annually When properly mainta...

Page 14: ...te control operation instructions for proper calibration and setup procedure Place batteries as needed in remote transmitters and battery powered receivers Place remote control out of reach of childre...

Page 15: ...caution when cleaning these areas Screw tips that have penetrated the sheet metal are sharp and should be avoided Remove all foreign objects Verify unobstructed air circulation Figure 4 3 IPI Pilot F...

Page 16: ...ing of the paint and the burning off of any oils remaining from manufacturing If appliance has not been used for some time dust can build up and cause an odor Film on the glass This is a normal result...

Page 17: ...le Check voltage of transformer at connection to module Acceptable read ings of a good transformer are between 6 4 and 6 6 volts DC Bat tery power supply voltage must be at least 4 volts If less than...

Page 18: ...sensing rod to white sensor wire Polish flame sensing rod with fine steel wool to remove any contaminants that may have accumulated on flame sensing rod Verify continuity with a multi meter with ohms...

Page 19: ...ard and will void the warranty Remote Controls Switches After a qualified service technician has installed the remote control follow the instructions supplied with the control installed to operate you...

Page 20: ...Parts Service Parts Topaz Beginning Manufacturing Date July 2014 Ending Manufacturing Date Active R TOPAZ IPI Part number list on following page Log Set Assembly Gas Stove DV 09 15 TOPAZ MBK IPI TOPA...

Page 21: ...0040MBK Mahogany 468 0040PMH Sienna Bronze 468 0040CSB 6 Top Black 468 0010MBK Mahogany 468 0010PMH Sienna Bronze 468 0010CSB 7 Shroud Upper Fan Qty 2 req 2340 130 8 Bracket Top Mounting Qty 2 req 23...

Page 22: ...inge Pin 844 5750 Y Magnet Round SRV7000 140 Y Thumbscrew 1 4 20 X 3 4 844 5070 Plate Support 2340 110 15 Screen Assembly Solitare 466 023 Quartet 466 021 16 Refractory Assembly BRICK TOPAZ Y 17 Glass...

Page 23: ...ce parts from your dealer or distributor Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER 22 1 Heat Shield J box 2342 132 22 2 Junction Box 4021 013 Y 22 3 Elbow 3 8 Flare Male 4021 045 22 4 Val...

Page 24: ...r distributor Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER 26 1 Starting Collar 2189 002 26 2 Gasket Adaptor 460 0610 26 3 Flue Assembly 2340 025 26 4 Relief Door Guide 2340 133 26 5 Relief...

Page 25: ...0A Y Temp Sensor Limit w Bracket 107 531A Y Firescreen Quartet Front Only 844 9360 Leveling Assembly 7000 000 Mineral Wool 050 721 Ori ce NG 32 Top Vent 582 832 Y Ori ce LP 50 Top Vent 582 850 Y Ori c...

Page 26: ...________________________________________________________________ ________________________________________________________________________________ ______________________________________________________...

Reviews: