18
7061-197P
August
13,
2018
Explorer II
Figure 18.3 - Completed View
Figure 18.1
Figure 18.2
C. Optional Fire Screen
An optional fire screen is available for the Explorer III.
Optional Fire Screen Part SCR-7061 may be used ONLY in
U.S. residential installations. Follow all safety warnings to
prevent any hazards.
Fire Risk.
•
Do not leave the fire unattended when the
door is unlatched or when using the fire
screen.
•
Unstable firewood could fall out of the
firebox creating a fire hazard to your home.
WARNING
Tools Required:
#2 & #3 Phillips head screwdriver; 1/2"
wrench
The flue collar is reversible for either a top or rear venting
installation. The appliance is shipped with the flue collar in
the top vent position.
Converting Collar Fo
r Rear Vent Installation
and Installing Required Horizontal Flue Shield
1.
Remove flue collar (#3 Phillips) and convection
chamber top (#2 Phillips)
(Figure 18.1)
.
2.
Remove 1 bolt from each side of the flue transition and
retrieve nuts attached to bolts
(Figure 18.2)
.
3.
Turn flue transition to horizontal position. Inspect rope
gasket to ensure a leak free seal. Re-attach.
4.
Remove upper flue cover from convection chamber
top. Rotate 180 degrees and reassemble. Use paint
supplied to cover unpainted areas.
5.
Reattach convection chamber top to flue collar to
appliance
(Figure 18.2)
.
D. Reversible Collar & Horizontal Flue Shield
Convection
chamber top
Flue collar
Flue transition
Upper flue cover