background image

 

      7061-197P 

   

August 

13, 

2018

Explorer II

D. Glass Specifications

This appliance is equipped with 5mm ceramic glass.  

Replace glass only with 5mm ceramic glass.  Please 

contact your dealer for replacement glass.

C. Mobile Home Approved (USA only)

G. Sleeping Room

H. California - Prop65

•  This appliance is approved for mobile home 

installations; when not installed in a sleeping room and 

when an outside combustion air inlet is provided.

• 

The structural integrity of the mobile home floor, ceiling, 

and walls must be maintained. 

•  The appliance must be properly grounded to the frame 

of the mobile home with #8 copper ground wire. 

•  Outside Air Kit, part OAK-ACC must be installed in a 

mobile home installation.

F. Combustible Materials

Material made of/or surfaced with any of the following 

materials: 

 

- Wood  

 

- Compressed Paper

 

- Plant Fibers   

- Plastic

 

- Plywood/OSB   

- Sheet Rock (drywall)

Any material that can ignite and burn: flame proofed or not, 

plastered or non-plastered. 

E. Non-Combustible Materials

Material which will not ignite and burn, composed of any 

combination of the following: 

 - 

Steel 

  - 

Plaster

 

- Brick   

 

- Iron

 - 

Concrete 

 - 

Tile

 - 

Glass 

  - 

Slate

Materials reported as passing ASTM E 136, Standard Test 

Method for Behavior of Metals, in a Vertical Tube Furnace 

of 750° C. 

Hearth & Home Technologies WILL NOT warranty 

appliances that exhibit evidence of over-firing.  Evidence of 

over-firing includes, but is not limited to:

• 

Warped air tube

•  Deteriorated refractory brick retainers

• 

Deteriorated baffle and other interior components

NOTE:

  Hearth & Home Technologies, manufacturer 

of this appliance, reserves the right to alter its 

products, their specifications and/or price without 

notice.

Improper installation, adjustment, alteration, service or 

maintenance can cause injury or property damage. 

For assistance or additional information, consult a qualified 

installer, service agency or your dealer.

• 

Installation and use of any damaged appliance. 

• 

Modification of the appliance.

• 

Installation other than as instructed by Hearth & 

Home Technologies.

• 

Installation and/or use of any component part not 

approved by Hearth & Home Technologies.

•  Operating appliance without fully assembling all 

components.

•  Operating appliance without legs attached (if 

supplied with appliance).

• 

Do NOT Over fire - If appliance or chimney connector 

glows, you are over firing.

Any such action that may cause a fire hazard.

WARNING

Fire Risk 

Hearth & Home Technologies disclaims any 

responsibility for, and the warranty will be voided 

by, the following actions: 

WARNING

This product and the fuels used to operate this product (wood), and 

the products of combustion of such fuels, can expose you to 

chemicals including carbon black, which is known to the State of 

California to cause cancer, and carbon monoxide, which is known to 

the State of California to cause birth defects or other reproductive 

harm. For more information go to: WWW.P65Warnings.ca.gov

When installed in a sleeping room it is recommended that 

a smoke and/or CO alarm be installed in the bedroom. The 

size of the room must be at least 50ft³ per 1,000 Btu/hr 

stove input, if the stove exceeds the room size, out air must 

be installed.

Summary of Contents for Explorer II series

Page 1: ...revendeur ou visitez www quadrafire com If the information in these instructions is not followed exactly a fire could result causing property damage personal injury or death WARNING Do not store or us...

Page 2: ...Chimney Termination Requirements 12 C 2 10 3 Rule 12 D Chimney Height Rise and Run 13 E Venting Components 13 F Chimney Systems 13 G Installing Chimney Components 15 H Proper Draft 15 5 Appliance Set...

Page 3: ...from the low and high EPA tests using Douglas Fir dimensional lumber A peak BTU out of the appliance calculated using the maximum first hour burn rate from the High EPA Test and the BTU content of cor...

Page 4: ...affle and other interior components NOTE Hearth Home Technologies manufacturer of this appliance reserves the right to alter its products their specifications and or price without notice Improper inst...

Page 5: ...chimney heights Ideal performance is with height of chimney between 14 16 feet 4 26 4 88m measured from the base of the appliance C Negative Pressure Negative pressure results from the imbalance of ai...

Page 6: ...ling winds during the heating season Ensure adequate outdoor air for all combustion appliances and exhaust equipment Ensure furnace and air conditioning return vents are not located in the immediate v...

Page 7: ...he party responsible for use and operation Hearth Home Technologies recommends the following Photographing the installation and copying this checklist for your file That this checklist remain visible...

Page 8: ...t View Figure 8 3 Side View 12 1 4 514MM 27 686mm 29 737mm 20 508mm 29 737mm Figure 8 2 Top View 13 3 8 340mm 7 8 22mm 2 3 8 60mm 25 7 8 657mm 3 8 9mm 29 737mm Figure 8 4 Side View with horizontal flu...

Page 9: ...he appliance See exception WARNING Fire Risk Hearth pads must be installed exactly as specified High temperatures or hot embers may ignite concealed combustibles Corner hearth pad dimensions with sing...

Page 10: ...4 1175 6 1 2 165 N A N A 55 1397 N A For alcove only Six inch diameter listed Double wall air insulated connector pipe with UL103 HT listed factory built Class A chimney or masonry chimney Maximum dep...

Page 11: ...space enclosed by the building envelope This helps to produce more draft especially during lighting and die down of the fire Penetrate the highest part of the roof This minimizes the affects of wind...

Page 12: ...or when there are other factors that affect flue draft B Chimney Termination Requirements Follow manufacturer s instructions for clearance securing flashing and terminating the chimney Figure 12 1 12...

Page 13: ...Listed Chimney Storm Collar Wall Support Roof Brace if required Thimble Figure 13 1 Prefabricated Exterior Chimney E Venting Components Chimney Connector It is also known as flue pipe or appliance pip...

Page 14: ...ey Figure 14 2 2 Entry hole to masonry chimney must be lined with an 8 inch 203mm minimum diameter clay liner or equivalent secured with refractory mortar 3 Construct a 17 inch x 17 inch 432mm x 432mm...

Page 15: ...is must be at least 24 gauge mild steel or 26 gauge blue steel The sections must be attached to the appliance and to each other with the crimped male end pointing toward the appliance All joints inclu...

Page 16: ...materials from packing box 2 Floor Rear Installation Cut a 4 inch 102mm hole in outside wall or floor to accommodate outside air piping Use 4 inch 102mm aluminum metal flex or rigid piping to directly...

Page 17: ...agnet under the bottom left rear corner See Owner s Manual for detailed operating instructions for the blower and snap disc Figure 17 1 Shock Risk Do NOT remove grounding prong from plug Route cord aw...

Page 18: ...op or rear venting installation The appliance is shipped with the flue collar in the top vent position Converting Collar For Rear Vent Installation and Installing Required Horizontal Flue Shield 1 Rem...

Page 19: ...ion requirements must be followed precisely 9 Use silicone to create an effective vapor barrier at the location where the chimney or other component penetrates to the exterior of the structure NOTE Of...

Page 20: ...20 7061 197P August 13 2018 Explorer II Date of Service Performed By Description of Service 7 Reference Materials A Service Maintenance Log...

Page 21: ...it Floor Rear OAK ACC Outside Air Collar Assembly 7033 039 Outside Air Shield 33271 Y Firescreen SCR 7061 FASTENERS Avk Rivnut Repair Kit 1 4 20 3 8 16 Rivnut Tools RIVNUT REPAIR Y Nut Ser Flange Smal...

Page 22: ...purchased installed _________________________________________________________________________ Serial Number ____________________________________ Location on appliance ___________________________ Deal...

Reviews: