background image

www.morsoe.com

Morsø P30/31

      

 

     Instructions for installation and use

Summary of Contents for P30

Page 1: ...www morsoe com Morsø P30 31 Instructions for installation and use ...

Page 2: ...0 Stoking technique Use of your stove 13 3 0 Regular maintenance of the stove 27 4 0 Technical data 38 MORSØ JERNSTØBERI A S DK 7900 NYKØBING MORS E Mail stoves morsoe com Website www morsoe com Instructions for installation and use Morsø P30 31 EN 14 785 ...

Page 3: ...re installation Please direct any queries to your Morsø dealer Prepare the location where the pellet stove is to be installed in accordance with local na tional and European legal requirements Incorrect installation or poor maintenance not in accordance with that described in this guidance can result in injury or damage to persons or objects Morsø accepts no civil or criminal liability in such an ...

Page 4: ...onal and local provisions must be complied with regard to the size of incombustible hearth required to cover the floor below the stove You should naturally ensure that the sheet can support the weight of the stove and possibly the steel chimney The hearth temperature beneath the P30 and P31 pellet stove does not excede 100 The chimney A modern efficient stove imposes greater requirements on your c...

Page 5: ...is not recommended as over a short time ash will hinder smoke flow and thus create problems for the draught to the stove A A B B A A 1 10 B B 1 10 Revisions Rev Sign Title Drawing no 1 5 Montering til skorsten Morsø P30 RSV 29 10 12 A3 31 0 ERROR materiale Date of print 30 10 2012 U udv Tegninger Pilleovn Morsø P30 Morsø P30 kofiguration 01A 070 MO 001A sldasm P30 08 a Itemno This drawing is Morsø...

Page 6: ...ide the house with another T piece outside to allow this stretch to be inspected Installing a 90 bend as the first piece is not recommended as over a short time ash will hinder smoke flow and thus create problems for the draught to the stove A A B B A A 1 10 B B 1 10 Revisions Rev Sign Title Drawing no 1 5 Montering til skorsten Morsø P30 RSV 29 10 12 A3 31 0 ERROR materiale Date of print 30 10 20...

Page 7: ...rd combustion is completely automatic and controlled The printed circuit board regulates the lighting phases 5 power steps extinguishing and thus guarantee safe function The majority of the ash created during combustion of the pellets drops into the ash drawer via the burn pot used for combustion In any event check the burn pot daily as not all pellets are of a high standard and can therefore leav...

Page 8: ...stove is provided with the most modern safety systems such that in the event of a fault in one of individual parts or in the flue the stove or habitable room cannot come to harm In all cases the pellet feed will immediately stop if a problem arises and extinguishing is activated The associated alarm will be shown on the display Further details are given in the chapter about alarms Open never the l...

Page 9: ...d off for each day of the week with up to four independent timings PROGRAMME 1 PROGRAMME 2 PROGRAMME 3 and PRO GRAMME 4 Example with 2 independent timings To access this menu use the following procedure 1 Keep key 4 pressed down for 3 seconds The text MENU 01 SET CLOCK is shown 2 Press key 4 once The display shows Menu 02 SET TIME 3 Press key 6 to allow access The display shows the desired screen ...

Page 10: ...nd turned off at 08 30 OFF 2 Tuesday PROG 1 On Tuesday the pellet stove is not turned on ON 3 Wednesday PROG 1 On Wednesday the pellet stove is to be turned on at 06 00 and turned off at 08 30 OFF 4 Thursday PROG 1 On Thursday the pellet stove is not turned on OFF 5 Friday PROG 1 On Friday the pellet stove is not turned on OFF 6 Saturday PROG 1 On Saturday the pellet stove is not turned on OFF 7 S...

Page 11: ...e main menu 2000 130 C AUGER 0 STATUS Rpm of smoke extraction motor Flue gas temperature Auger status Stove status Menu 05 STATUS operating status This menu can be used to check optimal setting of the most important parameters and some values that characterise optimal functioning of the stove Use the following procedure to ac cess the menu 1 Hold down key 4 for 3 seconds MENU 01 SET CLOCK appears ...

Page 12: ...10 34 21 ECO STOP Once the stove has shut down the display will show ECO STOP It will remain in this condition until the tempera ture decreases to approx 17 C when the stove will be re started NOTE The stove can turn off and on many times during the day This will mean more wear on the ignition tube The ignition tube is not covered by the guarantee Changing the room temperature setting The pellet s...

Page 13: ...ellet stove turned on the following procedure must be followed 1 Check that the system is connected to a chimney approved by the chimney sweep 2 Plug the power cable into the socket 3 Set the switch behind the stove to 1 4 Fill the pellet hopper with pellets that meet the quality requirements see page 14 5 Fill the auger as described in Automatic auger filling 6 Press key P3 for 3 seconds The pell...

Page 14: ... THE PELLET STOVE Overview of cleaning Parts frequency Daily 2 3 days 30 days 60 90 days Each season Burn pot p 27 Ash drawer p 28 Glass pane p 32 Smoke baffle p 29 Flue p 30 Glass fibre rope p 32 Cleaning rod p 28 Chimney p 7 Firebox p 29 Vacuum cleaning of pellet hopper p 32 Cleaning of surfaces Use a cloth wrung in water or mild soapy water to cleaning the enamelled metal parts Use of aggressiv...

Page 15: ...ccumulated during combustion We do not recommend using abrasive sponges or similar to remove more resistant slag as it can damage the thickness of the stones and create critical breakage points vacuum cleaning directly with the vacuum cleaner hose using a wet cloth to clean the stones The stones are heat resisting but not impact resisting Handle the stones carefully if they need to be moved The st...

Page 16: ...nguished and complete cold Unplug the power cable from the socket The pellet stove flues can be accessed from 3 points through the right hand inspection cover through the left hand inspection cover from the chimney bottom plate either a smoke door or removable bottom plug on the T piece Having gained access from these points soot can be removed using a brush and vacuum clea ner Access to inspectio...

Page 17: ...ellets in the hopper Empty the pellet hopper to check whether an object has fallen into it and preventing correct operation of the auger Adjust combustion see page 23 Refer to your Morsø dealer if the problem persists AL07 RESET THERMAL Thermal sensor with manual con nection reconnection is activated Convection fan is defective Combustion in the burn pot is not optimal Reset thermal sensor by pres...

Page 18: ...ules These Instructions for Use are an integral part of the product ensure that they always accom pany the pellet stove in the event of transfer to another owner or user or if it is moved to another position If the instructions are damaged or lost request a new copy from your Morsø dealer At the installation the user must be informed that The pellet stove especially its external surfaces reach ver...

Page 19: ...Installation not in accordance with current provisions in the country concerned Installation carried out by unqualified and untrained persons Alterations and repairs which have not been authorised by the producer Use of non original spare parts Extraordinary events Unsuitable chimney conditions 3 4 Guarantee conditions Morsø thanks you for the trust you have shown in us by purchasing our pellet st...

Page 20: ...mption during operation W 100W power step 5 nominal voltage V 230 nominal frequency Hz 50 All measurement data in accordance with test standard EN 14 785 Testing has been carried out by an accredited testing institution The Morsø P30 pellet stove is produced in accordance with these Directives 89 106 CEE structural materials 73 23 CEE electrical safety 2006 42 CEE machines 2004 108 CEE electromagn...

Page 21: ...40 Morsø Jernstøberi A S 10 03 2014 72301600 ...

Reviews: