32
AUG 2020
INSTALL GUIDE
6
MODULE WIRING
DS-200iQ / DS-600iQ
REV 00
6.1
DIP SWITCH SETTINGS
Once the modules have been connected, the DIP switches for the Versatile Feeder and
Flex Folder modules must be set (based on binary counting) as shown in Table 6.1.
DIP Switch ON Position
MODULE
SW1
SW2
SW3
SW4
1
X
2
X
3
X
X
4
X
5
X
X
6
X
X
7
X
X
X
8
X
Table 6.1 – DIP Switch settings
NOTE:
The module numbers refer to the Versatile Feeder and Flex Folder modules,
with the first feed unit being ‘
Module 1
’ and connected after the Insert Head.
The Insert Head is unwired, and the DIP switch is located on the processor board which
is set to 0000.
DIP switches for the Versatile Feeder and Flex Folder are located on the module
Control PCBs as shown in Figure 6.1.
QDT-RND-GEN-00000164-A-00
Figure 6.1 – Versatile Feeder and Flex Folder DIP Switch locations
The example illustration in Figure 6.2 shows the DIP switch set to Module 4.
QDT-RND-GEN-00000165-A-00
Figure 6.2 – DIP Switch set to Module 4
Summary of Contents for DS-200iQ
Page 1: ...INSTALL GUIDE DS 200iQ DS 600iQ...
Page 5: ...1 INSTALL GUIDE DS 200iQ DS 600iQ 1 SAFETY STANDARDS COMPLIANCE...
Page 11: ...7 INSTALL GUIDE DS 200iQ DS 600iQ 2 INTRODUCTION...
Page 14: ...10 INSTALL GUIDE DS 200iQ DS 600iQ 3 LIFTING KIT...
Page 19: ...15 INSTALL GUIDE DS 200iQ DS 600iQ 4 MODULE STANDS ASSEMBLY...
Page 24: ...20 INSTALL GUIDE DS 200iQ DS 600iQ 5 INSERT HEAD INSTALLATION...
Page 35: ...31 INSTALL GUIDE DS 200iQ DS 600iQ 6 MODULE WIRING...
Page 41: ...37 INSTALL GUIDE DS 200iQ DS 600iQ 7 SOFTWARE AND FIRMWARE...
Page 48: ...44 INSTALL GUIDE DS 200iQ DS 600iQ 8 DISPOSAL INSTRUCTIONS...