29
AUG 2020
INSTALL GUIDE
5
INSERT HEAD INSTALLATION
DS-200iQ / DS-600iQ
REV 00
2. Fit the BCR mount bracket to the support posts using 1 x countersunk head
screw in the lower support post, aligning the upper hole with the upper
support post as shown in Figure 5.18.
QTL-RND-OPS-00000189-A-00
Figure 5.18 – Attaching the BCR mount bracket
3. Fit the BCR locating mount plate to the mount bracket using the four pan
head screws. Ensuring the arrow marked on the plate is pointing downwards
as shown in Figure 5.19.
QTL-RND-OPS-00000190-A-00
Figure 5.19 – Fitting the locating mount plate to the BCR mount bracket
NOTE:
The locating mount plate is part of the BCR Hand-scanner (179-8890).
4. Remove the back cover of the monitor post and route the scanner cable
inside, securing it through the ‘P’ clips, and connecting the cable into any
available USB port on the PC. Switch on to check it is functioning, then refit the
back cover.