13
INQLINE SECUREMENT™ SYSTEM INSTALLATION
27" (685mm) - 34" (865mm)
1. Choose the installation location for the INQLINE
SECUREMENT™ Retractors, measure from the middle
left retractor webbing to the middle right retractor
webbing a minimum distance of 27” (685mm) to a
maximum distance of 34” (865mm). Then with an
erasable grease pencil trace the outside of the retractors
(
A
). Remove the INQLINE SECUREMENT™ Retractors
from the floor.
Make sure retractors are installed leveled and straight or at
a maximum 5 degrees inward angle (
A1
). Reference
Location Recommendation Section if any questions arise
or contact the nearest Q'STRAINT® office for further
assistance.
2. Place the left and right retractor templates
(For cut
out Left and Right Retractor Templates, go to pages 15
& 16)
on top ofthe floor markings and with an erasable
grease pencil mark the 6 holes for the securement of
the INQLINE SECUREMENT™ Retractors (
B
).
If the vehicle does not align with these recommendations
contact the nearest Q'STRAINT® office for further
assistance.
3. Remove left and right retractor templates and drill ½”
(12.7mm) holes through the 6 marked holes on the floor
and clean debris (C).
Before drilling, inspect the underside of the vehicle for
any obstructions.
A
A1
B
C
Left
Right
27" (685mm) - 34" (865mm)
Left
Right
Left
Right
DRILL
Maximum 5 Degrees Inward Angel