141
•
System maintenance events
Level
Type
Description
INFO
System shutdown
System shutdown.
INFO
System reboot
System reboot.
INFO
System console
shutdown
System shutdown from <string> via Console UI
INFO
System web
shutdown
System shutdown from <string> via Web UI
INFO
System button
shutdown
System shutdown via power button
INFO
System LCM
shutdown
System shutdown via LCM
INFO
System console
reboot
System reboot from <string> via Console UI
INFO
System web reboot
System reboot from <string> via Web UI
INFO
System LCM reboot
System reboot via LCM
INFO
FW upgrade start
System firmware upgrade starts.
INFO
FW upgrade
success
System firmware upgrade succeeds.
WARNING
FW upgrade failure
System firmware upgrade is failed.
ERROR
IPC FW upgrade
timeout
System firmware upgrade timeout on another controller
INFO
Config imported
<string> config imported
•
HAC events
Level
Type
Description
INFO
RG owner changed
The preferred owner of RG <name> has been changed to
controller <number>.
INFO
Force CTR write
through
Controller <number> forced to adopt write-through mode on
failover.
INFO
Restore CTR cache
mode
Controller <number> restored to previous caching mode on
failback.
INFO
Failover complete
All volumes in controller <number> completed failover
process.
INFO
Failback complete
All volumes in controller <number> completed failback
process.
INFO
CTR inserted
Controller <number> is inserted into system
ERROR
CTR removed
Controller <number> is removed from system
ERROR
CTR timeout
Controller <number> gets no response
ERROR
CTR lockdown
Controller <number> is locked down
ERROR
CTR memory NG
Memory size mismatch
ERROR
CTR firmware NG
Firmware version mismatch
ERROR
CTR lowspeed NG
Low speed inter link is down
ERROR
CTR highspeed NG
High speed inter link is down
ERROR
CTR backend NG
SAS expander is down
ERROR
CTR frontend NG
FC IO controller is down
INFO
CTR reboot FW
sync
Controller reboot, reason [Firmware synchronization
completed]
Summary of Contents for P300H61
Page 79: ...79 ...
Page 110: ...110 Figure 5 7 1 2 ...
Page 145: ...145 This form can be got from QSAN ftp ftp ftp qsan com tw QSAN_Support_Form doc ...
Page 148: ...148 Figure B 1 3 Click Done Figure B 2 Figure B 3 ...
Page 151: ...151 Figure B 8 Figure B 9 15 Click Add 16 Click Advanced ...
Page 153: ...153 Figure B 14 22 Done the iSCSI device disconnect successfully ...
Page 154: ...154 System information P300H61 P300H71 SW version 2 0 1 ...