Number
Input
types
Operation
21
Entry
Shock
Active when system armed: This input type is advised to be used in conjunction with an Entry Delay
input. The Entry Delay input is a door contact on the initial entry door, and the Entry Shock input is a
non-latching shock sensor fitted to the door frame in the vicinity of the lock. If the door is forced a
Burglary alarm will be generated immediately instead.
22
Line Fault
Active when fail. This input type is used to detect external transmission equipment line fail (output). If
activated it will give a line fault alarm, and will signal telecom line fault on expiry of line fault timer. It
can be used in conjunction with CCTV input (type 39)
23
Keyswitch
Pulsed*
Accepts input from keyswitch to arm/disarm the area(s) assigned to it. Requires momentary action
switch to toggle arm/disarm state.
Note that Grade 1 operation only allows arming from the push button, but requires means to abort
arming (not to disarm)
39
CCTV
Active at all times: No audible alarm or communicator response.
The CCTV input should be connected to an external detector located next to a CCTV camera. An
output can be programmed to follow this input and the output should be connected to a CCTV
recording, transmission or other device. An input programmed as “Line Fault” (input type 22) should
also be connected to an output of the CCTV transmission Device. If the CCTV transmission line has
been cut or missing the ‘Line Fault’ input will activate. Following this, at each activation of the CCTV
input the panel will signal CID events for ‘Silent Burglary’ and Line Fault. No audible alarm will be
created. If the Line Fault is not active it will just log the activations of the CCTV input into the event
log.
41
Patrol /
Keybox
This input type will work similarly to a switcher input, it does not trigger an alarm but will report
Contact ID event 250 and is also a useful input type when an output is required to follow the ‘Keybox’
type input.
42
Medical
This is a 24 Hrs type input it will activate the external sounder and report a Contact ID event 100.
43
Entry
Delay 2$
Any input programmed as Entry Delay 2 will act as input type 07, but the associated entry timer will
use Entry Timer 2, rather than Entry Timer 1.
44
Silent
Medical
Active at all times. Audible Response: None. Reports a Contact ID event 100.
By default, all inputs are set to ‘unused’.
# These inputs cannot be bypassed.
* Use of these inputs will make the system unable to comply with EN50131-1 Security Grade 2.
$ Ensure that these inputs are used on an entry/exit route
Output Types
No.
Output
Type
Active
Restore
0000
Not Used
0001
Fire
At fire alarm activation
When a valid code is entered
0002
PA Any
At personal attack activation
When a valid code is entered
0003
Burglary Any
At burglary alarm from any area
At first valid code entry
0004
Final Arm All
When ALL areas are armed
At code entry to disarm
70
Enforcer Installation Guide
102017854 - V01