No.
Output
Type
Active
Restore
0005
Open After
Alarm (Abort)
When system is silenced after ‘burglary’ alarm
has been activated
After 2 minutes
0007
Tamper Any
Tamper alarm in any area
At code entry to silence
0008
Duress Any
At a Duress alarm in any area
When a valid code is entered
0009
PA Device Any
At alarm on a PA input only from any area. (This
does not include the keypad PA)
When a valid code is entered
0010
Gas
At gas alarm
When a valid code is entered
0011
Arm Fail
Pre-set time after start of exit time, if exit
procedure is not complete
At code entry to rearm
0012
Entry
Deviation
When deviation from entry route occurs, during
entry time
At code entry to disarm
0013
System Ready
Any
When any of the inputs but the Entry Delay and
Follow are closed
If fault exists, and after final arm
0014
Bell Any
After alarm in any area
When alarm silenced or when siren timer expires
0016
Strobe Any
After alarm in any area
When disarmed or when strobe timer expires
0017
Bypass Rearm
Any
When inputs are bypassed at rearm in any area
When system disarmed
0018
Burglary
(Unconfirmed)
Any
At Burglary alarm in any area
At code entry to silence
0019
Ready All
When all inputs but the ‘Entry Delay’ and ‘Follow’
inputs are closed
If fault exists, and after final arm
0020
Exit Starts All
At start of exit time to arm LAST area
At disarm FIRST area (i.e. no longer fully armed)
0021
Exit Starts
Any
When exit time starts to arm FIRST area
At code entry to disarm LAST area
0022
Final Arm Any
When ANY area has been armed
At code entry to disarm LAST area
0023
Strobe if Arm
Fail
Works similar to output 016, but also fires if the ‘arm fail’ timer expires
0024
Unable to
Arm
This output turns on for 5 seconds when the system is disarmed via a keyswitch input (either pulsed
or latched keyswitch)*
0025
Keyswitch
Disarm
Output activates when an arming procedure is completed with inputs bypassed
0026
Arm with
Bypass
Active when the system is armed with an input bypassed
0027
Pulsed
Burglary Any
Active when burglary alarm is triggered, but deactivates once the Pulsed Intruder timer has expired
0028
Power Fault
Active during low volts and battery faults. Restores at code entry after fault cleared
0031
Entry
Active during any Entry time
0032
Exit
Active during any Exit time
0033
Entry / Exit
Active during any entry or exit time
0034
Lights
When exit or entry timer starts
20 seconds after arm/disarm procedure
completed
Enforcer Installation Guide
102017854 - V01
71