Fault
Description
Solution
WLs Supervn Fault
No ‘supervision polls’ were received for 20
minutes before the arming operation. Wireless
Input or Bell input number will be shown so the
problem is easily identified.
Test the signal strength / battery on each
wireless device
WLs Input / Input Type
Mismatch
Wireless devices are learned on Inputs but no
zone types have been programmed for them.
Program input type for each wireless device
learned in the PROGRAM INPUTS.
Wireless Keypad x WLs
Supervn Fault
No 'supervision polls' have been received by the
panel for 20 minutes or the length of the
'supervision timer'. Wireless keypad number will
be shown.
Test the signal strength and the battery on each
wireless keypad.
Table 17 - Errors When Arming
Fault
Description
Solution
Please leave via exit
door
If the exit mode is programmed as Entry Delay,
then you must leave through that door to arm
the system.
Leave via the agreed exit route.
Exit Via…
If any follow detectors or door contacts are
open during the arming procedure, this prompts
you to close them.
Close all Inputs.
Unable To Arm
A fault condition exists on the system. Details of
the fault will scroll on the display.
Correct the problem if it is an input which is
open, or call engineer.
Alarm during the
arming
Fail to arm time has been exceeded.
Leave the premises within the fail to arm time,
increase the fail to arm time in timers or disable
this feature in system options.
Alarm during the
arming procedure
Instant Inputs have been activated.
During the arming procedure do not activate
instant Inputs.
Support contact details
Email: [email protected]
Website: www.pyronix.com