Technical Specifications
Table 4 - Mains Inputs
European rated voltage
230V AC -15/+10%
European rated current
63mA
Capable operating voltage
90 - 264V AC
Current
222 - 75mA
Rated Frequency
50 / 60Hz
Input Fuse Rating
T 2A (non-replaceable)
PSU
Type A
Radio Frequency
FM Transceiver Narrow
Physical Dimensions
220 x 160 x 50mm
Weight
1025g
Environmental
Operating Temperature
-10°C to +40°C
Storage Temperature
-20°C to +60°C
Table 5 - I/O Board (if connected)
Belgium installations: To guarantee compliance with the standard T014A no load shall be connected
to the I/O board.
Output Voltage
9-16VDC (12V nom.)
Max Current Output
0.07A allowed
PGM/BELL/STB Outputs
250mA Continuous Load
BELL / Aux Fuses
500mA, Quick Blow
Table 6 - Electrical (Keyfob, PIR and Contact)
Operating Voltage
3.0V nominal
Current (Communicating)
Consumption:
40-80-mA
250mA Continuous Load
Comms Time
40ms + 40ms
Battery Type (KF)
BATT-CR1/3N(KF4 MK2)
Battery Type (PIR)
BATT-CR123A
Battery Type (UT)
BATT-CR2
Table 7 - Environment: All Devices
Nominal operating temperature
-10°C to +50°C
Certified operating temperature
-10°C to +40°C
Storage temperature
-40°C to +80°C
62
Enforcer Installation Guide
102017854 - V01