4-2
VIBXPER
T II 05.2012
Evaluating results
Before a result is evaluated, make sure that the measurement is valid
and no error message is present (see page 2-2).
Result details
The following information can be displayed:
- Measurement Task, Measurement Channel, Measurement Range,
- Sensor Type, Date/Time, Status
- Statistical Data (for overall values only)
• Press MENU and click on 'Result Details'.
Characteristic overall value - single values
Up to two overall values are simultaneously displayed in the result
screen. The RPM appears in the lower area. If the threshold values are
exceeded during the measurement, these appear in the field below
the respective measurement value (see below). Also, the respective
LED lights up next to the display (see pages 2-2). Thresholds can be
displayed as an absolute value or as a difference to the measurement
value.
For vibration parameters with more than two overall values*, press
the navigation key up / down to display the other values (see 'Display
Setup', page 4-17).
* e.g.: Vibration parameters with 6 overall values:
1. rms value
2. 0-p value
3. p-p value
4. 0-p calculated (= RMS x
√
2)
5. p-p calculated (= 0-p x 2)
6. Crest factor (s. P. 5-1)
Results
Left:
Result screen for overall value
Right:
Resultdetails
RMS value
(no threshold value exceeded)
0-P value
(alarm exceeded by 1.387 mm/s)
Summary of Contents for VIBXPERT II
Page 175: ......