Getting started - Basic settings
Measurement settings
• Click on 'Measurement' to set up the following options:
Autostart measurement
This shortens the duration of the entire measurement.
-
e
naBled
: Clicking the measurement location starts the first mea-
surement automatically. If multiple measurement tasks are defined
for the same accelerometer at a single measurement location, these
measurement tasks are automatically run consecutively, provided
that the 'Auto Save' option is enabled (see next section).
-
d
isaBled
: The first measurement at a measurement location must
be started manually.
Autostart MUX
This options shortens the time between the measurements.
-
a
ctivated
: The measurements start automatically as soon as a mul-
tiplexer measurement location is opened in the selection screen.
-
d
eactivated
: The measurements have to be started with ‘Enter’.
Route optimizer
This function optimizes the processing of the route and shortens the
time involved in collecting the measurement data.
-
e
naBled
:
Measurement tasks for a measurement location with the
same sensor are processed one after the other.
-
d
isaBled
:
Measurement tasks are processed in the sequence in
which they were created in OMNITREND.
Optimize meas. time for MultiTask
The individual measurements are performed with a sensor but are
processed in parallel on 2 channels in VIBXPERT.
-
e
naBled
: Measurements are internally distributed to both measure-
ment channels and are processed in parallel.
-
d
isaBled
: Measurements are performed in sequence on one chan-
nel.
Left:
Basic settings for the route/
template operating mode
Right:
Setting up the measurement