2-20
VIBXPER
T II 05.2012
Getting started - Basic settings
Transducer parameters
for VIB 6.122 accelerometer
*'Show' appears for factory-defined
transducers whose parameters cannot
be changed.
1
only for VIBREX / VIBRONET
² only for 'Voltage' signal type
Transducer parameters
To check the parameters for transducers that have already been set
up, proceed as follows:
• Select the transducer.
• Press the MENU key.
• Click on 'Show'* or 'Edit' to open the parameter screen (see below).
m
eas
.
quantity
Measurement quantity of the sensor: vibration acceleration, veloc-
ity, displacement, current, RPM, jump, user-defined quantity
s
ignal
type
Signal type of the sensor (e.g. LineDrive, ICP, voltage)
i
nput
voltage
range
±3V / ±8V
1
/ ±30V²; only applies for transducers of 'Voltage', Cur-
rent', 'ext. 5V converter' and 'VIBREX/VIBRONET' signal types.
q
uantity
(
user
def
.)
Identification for a user-defined measurement variable.
u
nit
(
user
.
def
.)
Unit for the user-defined variable.
p
recision
Accuracy in decimal places.
c
oefficient
a
4,
a
3,
a
2
Parameters for linearizing a sensor's non-linear characteristic line
(e.g. MNS12 proximity probe - VIB 6.640).
s
ensitivity
The sensitivity of the sensor determines the signal level.
o
ffset
Offset of the sensor
l
inear
from
/
to
The linearity range of the sensor and the filter setting of the mea-
surement must be adapted to one another.